Appendix A – PROFIdrive parameters 185
927
R/W
Unsigned16
Operator control rights (parameter
identification, PKW)
928
R/W
Unsigned16
Control rights (process data, PZD).
929
R
Unsigned16
Selected PPO type
Par. no. R/W
1)
Data type
Description
Value Mode
0
Parameters cannot be written,
only read (927 can be written).
1
Parameters can be written and
read (default).
Value Mode
0
PZD part is disabled, ie,
Receipt of new PZD data is
ignored.
1
PZD part is enabled (default).
Value PPO type Configuration
1
PPO1
F3h, F1h
2
PPO2
F3h, F5h
3
PPO3
F1h
4
PPO4
F5h
5
PPO5
F3h, F9h
6
PPO6
F9h
7
PPO7
0xF3, 0xFB
8
PPO8
0xFB
Note:
This parameter is not available if
standard telegram ST1 or ST2 is
selected.