Communication profiles 103
6
1
Normal operation.
Proceed to
OPERATING
.
Note:
This bit is
effective only if the
fieldbus interface is
set as the source for
this signal by drive
parameters.
Activate traversing
task (0
→
1). This is
a toggle bit; each
rising edge of signal
enables a traversing
task or a new set
point.
0
Force Ramp
Function Generator
input to zero.
7
RESET
0
→
1 Fault reset if an active fault exists. Proceed
to
SWITCH-ON INHIBIT.
Note:
This bit is effective only if the fieldbus
interface is set as the source for this signal
by drive parameters.
0
(Continue normal operation)
8
JOGGING_1
Jogging 1 (Not supported by all drive types)
9
JOGGING_2
Jogging 2 (Not supported by all drive types)
10
REMOTE_
CMD
1
Fieldbus control enabled
0
Control word <> 0 or reference <> 0: Retain
last Control word and reference.
Control word = 0 and reference = 0:
Fieldbus control enabled.
11
1
Vendor-specific bit
as defined by
PROFIdrive
parameter
933
.
Start homing
procedure.
0
Stop homing
procedure.
12
Vendor-specific bit as defined by
PROFIdrive parameter
934
13
Vendor-specific bit as defined by
PROFIdrive parameter
935
Bit
Name
Value
STATE/Description
Speed control
mode
Positioning mode
Summary of Contents for FPBA-01 PROFIBUS DP
Page 4: ......
Page 10: ...10 Table of contents Document library on the Internet 195 ...
Page 20: ...20 About the manual ...
Page 26: ...26 Overview of the PROFIBUS network and the FPBA 01 module ...
Page 30: ...30 Mechanical installation ...
Page 91: ...Start up 91 8 Click Properties Network Settings and set baud rate ...
Page 98: ...98 Start up ...
Page 118: ...118 Communication profiles ...
Page 178: ...178 Diagnostics ...
Page 182: ...182 Technical data ...