88 Communication profiles
References
References are 16-bit words containing a sign bit and a 15-bit
integer. A negative reference (indicating reversed direction of
rotation) is formed by calculating the two’s complement from the
corresponding positive reference.
ABB drives can receive control information from multiple sources
including analog and digital inputs, the drive control panel and a
communication module (for example, FEPL-02). To have the drive
controlled through the fieldbus, the module must be defined as the
source for control information, for example, reference.
Scaling
References are scaled as shown below.
Note:
The values of REF1 MAX and REF2 MAX are set with drive
parameters. See the drive manuals for further information.
In ACSM1, ACS850, ACQ810 and ACS880, the speed reference
(REFx) in decimal (0…20000) corresponds to 0…100% of the
speed scaling value (as defined with a drive parameter, eg,
ACS880 parameter
46.01 Speed scaling
).
In ACS355, drive parameter REFx MIN may limit the actual
minimum reference.
Drive
Fieldbus
0
REFx MAX / Speed scale
-(REFx MAX) / Speed scale
0
REF2: -10000
REF1: -20000
REF2: 10000
REF1: 20000
Summary of Contents for FEPL-02 Ethernet POWERLINK
Page 4: ......
Page 10: ...10 Table of contents ...
Page 20: ...20 About the manual ...
Page 28: ...28 Mechanical installation ...
Page 63: ...Start up 63 2 To add the adapter module right click the IF3 list entry and then click Insert ...
Page 69: ...Start up 69 3 In the Project transfer dialog box click OK 4 Wait for the transfer to finish ...
Page 70: ...70 Start up When the transfer is finished the PLC starts up in the RUN mode ...
Page 90: ...90 Communication profiles ...
Page 100: ...100 Communication protocol ...
Page 104: ...104 Diagnostics ...
Page 108: ...108 Technical data ...