Appendix A – CANopen Object Dictionary 111
Communication profile objects
The objects in the communication profile section describe the basic
Ethernet POWERLINK properties of the adapter module. The
objects are described in the following table.
Index
SI
Name
Type
Acc.
Def.
Information
1000
0
Device type
U32
R
0x10192
Describes the type of the
device. Composed of two 16-
bit fields, the least significant
field describing the device
profile, and the most
significant field giving
additional information.
The device profile for FEPL-02
is 0×10192 (hex), which
corresponds to communication
profile CiA 402, and additional
information value is 0×01
(hex), which represents a
frequency converter.
1001
0
Error register
U8
R
0
Error register for the adapter
module. Bit encoded
according to DS 301/401.
When a bit is set, the error is
active. Bits:
• 7: Manufacturer-specific
• 6: Reserved (always 0)
• 5: Device profile specific
• 4: Communication
• 3: Temperature
• 2: Voltage
• 1: Current
• 0: Generic error (any drive
fault).
1003
0
Error history
U8
RW
0
Number of entries.
0 = clear history
Range: 0…254
1
Error entry 1
R
-
…
…
…
…
…
254 Error entry
254
R
-
1006
0
Communica-
tion cycle
time interval
U32
R
0
Length of the cycle time
interval in microseconds, ie,
the time between SoC-SoC
Summary of Contents for FEPL-02 Ethernet POWERLINK
Page 4: ......
Page 10: ...10 Table of contents ...
Page 20: ...20 About the manual ...
Page 28: ...28 Mechanical installation ...
Page 63: ...Start up 63 2 To add the adapter module right click the IF3 list entry and then click Insert ...
Page 69: ...Start up 69 3 In the Project transfer dialog box click OK 4 Wait for the transfer to finish ...
Page 70: ...70 Start up When the transfer is finished the PLC starts up in the RUN mode ...
Page 90: ...90 Communication profiles ...
Page 100: ...100 Communication protocol ...
Page 104: ...104 Diagnostics ...
Page 108: ...108 Technical data ...