Appendix A – CANopen Object Dictionary 123
6046
0
vi velocity min
max amount
I8
R
2
Minimum and maximum
velocity absolute value
settings for the velocity
operation mode (vl)
1
min abs
velocity
U32
RW
-
Velocity absolute value
minimum
2
max abs
velocity
U32
RW
-
Velocity absolute value
maximum
6048
0
vl velocity
acceleration
I8
R
2
Acceleration ramp settings for
the velocit6y operation mode
(vl)
1
Delta speed
U32
RW
-
Ramp delta speed (vl scaling
units).
Note:
Read only in ACS355
and ACS880.
2
Delta time
U16
RW
-
Ramp delta time (s)
6049
0
vl velocity
deceleration
I8
R
2
Deceleration ramp settings for
the velocity operation mode
(vl)
1
Delta speed
U32
RW
-
Ramp delta speed (vl scaling
units).
Note:
Read only in ACS355
and ACS880.
2
Delta time
U16
RW
-
Ramp delta time (s)
604A
0
vl velocity
quick stop
I8
R
2
Quick stop ramp settings for
the velocity operation mode
(vl)
1
Delta speed
U32
RW
-
Ramp delta speed (vl scaling
units).
Note:
Read only in ACS355
and ACS880.
2
Delta time
U16
RW
-
Ramp delta time (s)
604C
0
vl dimension
factor
I8
R
2
Velocity data scaling factor for
the velocity operation mode
(vl). Basic unit in the vl
operation mode is rpm.
1
numerator
I32
RW
-
Default: 1
2
denominator
I32
RW
-
Default: 1
605B
0
Shutdown
option code
I16
RW
0
0 = coast stop (default)
1 = ramp stop
Index SI
Name
Type
Acc.
Def.
Information
Summary of Contents for FEPL-02 Ethernet POWERLINK
Page 4: ......
Page 10: ...10 Table of contents ...
Page 20: ...20 About the manual ...
Page 28: ...28 Mechanical installation ...
Page 63: ...Start up 63 2 To add the adapter module right click the IF3 list entry and then click Insert ...
Page 69: ...Start up 69 3 In the Project transfer dialog box click OK 4 Wait for the transfer to finish ...
Page 70: ...70 Start up When the transfer is finished the PLC starts up in the RUN mode ...
Page 90: ...90 Communication profiles ...
Page 100: ...100 Communication protocol ...
Page 104: ...104 Diagnostics ...
Page 108: ...108 Technical data ...