84 Communication profiles
3
INHIBIT_
OPERATION
1
Proceed to
OPERATION ENABLED
.
Note:
Run enable signal must be active;
see drive documentation. If the drive is set
to receive the Run enable signal from the
fieldbus, this bit activates the signal.
0
Inhibit operation. Proceed to
OPERATION
INHIBITED
.
4
RAMP_OUT_
ZERO
1
Normal operation. Proceed to
RAMP
FUNCTION GENERATOR: OUTPUT
ENABLED
.
0
Force Ramp Function Generator output to
zero. Drive ramps to stop (current and DC
voltage limits in force).
5
RAMP_HOLD
1
Enable ramp function.
Proceed to
RAMP FUNCTION
GENERATOR: ACCELERATOR
ENABLED
.
0
Halt ramping (Ramp Function Generator
output held).
6
RAMP_IN_
ZERO
1
Normal operation. Proceed to
OPERATION
.
Note:
This bit is effective only if the
fieldbus interface is set as the source for
this signal by drive parameters.
0
Force Ramp Function Generator input to
zero.
7
RESET
0
→
1 Fault reset if an active fault exists.
Proceed to
SWITCH-ON INHIBITED
.
Note:
This bit is effective only if the
fieldbus interface is set as the source for
this signal by drive parameters.
0
Continue normal operation.
8…9 Reserved.
Bit
Name
Value
STATE/Description
Summary of Contents for FEPL-02 Ethernet POWERLINK
Page 4: ......
Page 10: ...10 Table of contents ...
Page 20: ...20 About the manual ...
Page 28: ...28 Mechanical installation ...
Page 63: ...Start up 63 2 To add the adapter module right click the IF3 list entry and then click Insert ...
Page 69: ...Start up 69 3 In the Project transfer dialog box click OK 4 Wait for the transfer to finish ...
Page 70: ...70 Start up When the transfer is finished the PLC starts up in the RUN mode ...
Page 90: ...90 Communication profiles ...
Page 100: ...100 Communication protocol ...
Page 104: ...104 Diagnostics ...
Page 108: ...108 Technical data ...