122 Appendix A – CANopen Object Dictionary
CiA 402 profile objects
The CiA 402 profile objects describe objects for monitoring and
controlling frequency controllers. The objects are described in the
following table.
Index SI
Name
Type
Acc.
Def.
Information
603F
0
Error code
U16
R
0
CiA 402 error code of the
last
error which occurred in the
drive. Values according to IEC
61800-7-201. Manufacturer-
specific error codes
0xFF00...0xFFFF: In general,
all drive fault codes from
0xFF00 and above pass
straight through into this
object. Two error codes are
generated by the adapter
module:
• 0xFFE1: Failed to read
fault code from the drive.
• 0xFFFF: Unhandled drive
fault code - corresponding
CiA 402 error code does
not exist.
See object 2201 and the drive
manual.
6040
0
Control word
U16
RW
-
CiA 402 control word
6041
0
Status word
U16
R
-
CiA 402 status word
6042
0
vl target
velocity
I16
RW
-
Effective in the velocity
operation mode (vl)
6043
0
vl velocity
demand
I16
R
-
Operational if the ramp
function generator output
(CI 61) is available from the
drive. Cyclic low priority
communication.
Note:
Not available with
ACS355.
6044
0
vl velocity
actual value
I16
R
-
Operational when velocity
feedback is available from the
drive
Summary of Contents for FEPL-02 Ethernet POWERLINK
Page 4: ......
Page 10: ...10 Table of contents ...
Page 20: ...20 About the manual ...
Page 28: ...28 Mechanical installation ...
Page 63: ...Start up 63 2 To add the adapter module right click the IF3 list entry and then click Insert ...
Page 69: ...Start up 69 3 In the Project transfer dialog box click OK 4 Wait for the transfer to finish ...
Page 70: ...70 Start up When the transfer is finished the PLC starts up in the RUN mode ...
Page 90: ...90 Communication profiles ...
Page 100: ...100 Communication protocol ...
Page 104: ...104 Diagnostics ...
Page 108: ...108 Technical data ...