Def / Type
FbEq 16b / 32b
Description
Name / Range /
Selection
No.
False / int32
Selects the source of a jog signal (in the negative
direction).
This command is always level-triggered.
In case jogging is activated in both the positive and
negative directions, the one that was activated last
takes priority.
For the selections, see
.
Jog reverse sel
74.23
User Position CW1 bit
4 / int32
Selects the source of a signal that activates the preset
functionality defined in
.
This command is always edge-triggered.
For the selections, see
.
Set position sel
74.24
- / int32
Selects the source of a signal that activates homing.
Parameter
74.15 Position command trigger type
defines
whether the command is edge-triggered or
level-triggered.
For the selections, see
.
Homing sel
74.25
False / int32
Selects the source of a signal that activates the move
in velocity mode function. Parameter
defines whether the command
is edge-triggered or level-triggered.
For the selections, see
.
Velocity sel
74.26
User Position CW1 bit
6 / int32
Selects the source of a signal that activates the move
relative function. Parameter
defines whether the command is
edge-triggered or level-triggered.
For the selections, see
.
Relative sel
74.27
User Position CW1 bit
7 / int32
Selects the source of a signal that activates the move
absolute function. Parameter
defines whether the command is
edge-triggered or level-triggered.
For the selections, see
.
Absolute sel
74.28
False / int32
Selects the source of a signal that activates or provides
the start command for the position index functionality.
Parameter
74.15 Position command trigger type
defines
whether the command is edge-triggered or
level-triggered.
For the selections, see
.
Position index sel
74.29
- / int32
Selects the path direction together with
. See
, bit 10. This command is always level-triggered.
For the selections, see
.
Path direction bit 0
sel
74.30
False / int32
Selects the path direction together with
. See
, bit 11. This command is always level-triggered.
For the selections, see
.
Path direction bit 1
sel
74.31
False / int32
Selects the source of a signal that activates the gear-in
function. Parameter
74.15 Position command trigger
defines whether the command is edge-triggered
or level-triggered.
For the selections, see
.
Gear in sel
74.32
446 Parameters
Summary of Contents for ACS880 N5700 Series
Page 1: ... ABB INDUSTRIAL DRIVES ACS880 position control program N5700 Firmware manual ...
Page 2: ......
Page 4: ......
Page 22: ...22 ...
Page 28: ...28 ...
Page 32: ...32 ...
Page 60: ...60 ...
Page 546: ...546 ...
Page 604: ...604 ...
Page 626: ...626 ...
Page 640: ...640 ...
Page 660: ...660 ...