0.00 Hz / real32
Defines a frequency corresponding to a zero reference
received from fieldbus (either the embedded fieldbus
interface, or interface FBA A or FBA B). For example,
with a setting of 30, the fieldbus reference range of
0…20000 would correspond to a speed of 30…[
Hz.
Note: This parameter is effective only with the ABB
Drives communication profile.
Frequency ref zero
scaling
46.7
10 = 1 Hz / 100 = 1 Hz
Frequency corresponding to minimum fieldbus
reference.
0.00 ... 1000.00 Hz
500 ms / real32
Defines a filter time for signals
and
Filter time motor
speed
46.11
1 = 1 ms / 1 = 1 ms
Motor speed signal filter time.
0...20000 ms
500 ms / real32
Defines a filter time for signal
Filter time output
frequency
46.12
1 = 1 ms / 1 = 1 ms
Output frequency signal filter time.
0...20000 ms
100 ms / real32
Defines a filter time for signal
Filter time motor
torque
46.13
1 = 1 ms / 1 = 1 ms
Motor torque signal filter time.
0...20000 ms
100 ms / real32
Defines a filter time for signal
Filter time power
out
46.14
1 = 1 ms / 1 = 1 ms
Output power signal filter time.
0...20000 ms