Def / Type
FbEq 16b / 32b
Description
Name / Range /
Selection
No.
- / real32
Measured DC link voltage.
DC voltage
1.11
10 = 1 V / 100 = 1 V
DC link voltage.
0.00 ... 2000.00 V
- / real32
Calculated motor voltage in V AC.
Output voltage
1.13
1 = 1 V / 1 = 1 V
Motor voltage.
0...2000 V
- / real32
Drive output power. The unit is selected by parameter
. A filter time constant for this signal
can be defined by parameter
Output power
1.14
- / -
Output power. For scaling, see parameter
.
-32768.00 ...
32767.00 kW or hp
- / real32
Shows the value of
in percent of the
nominal power of the motor.
Output power % of
motor nom
1.15
10 = 1 % / 100 = 1 %
Output power.
-300.00 ... 300.00 %
- / real32
Estimated mechanical power at motor shaft. The unit
is selected by parameter
. A filter
time constant for this signal can be defined by
parameter
.
Motor shaft power
1.17
1 = 1 kW or hp / 100 =
1 kW or hp
Motor shaft power.
-32768.00 ...
32767.00 kW or hp
- / int16
Amount of energy that has passed through the drive
(towards the motor) in full gigawatt-hours. The
minimum value is zero.
Inverter GWh
motoring
1.18
1 = 1 GWh / 1 = 1 GWh
Motoring energy in GWh.
0...32767 GWh
- / int16
Amount of energy that has passed through the drive
(towards the motor) in full megawatt-hours. Whenever
the counter rolls over,
is
incremented. The minimum value is zero.
Inverter MWh
motoring
1.19
1 = 1 MWh / 1 = 1 MWh
Motoring energy in MWh.
0...1000 MWh
- / real32
Amount of energy that has passed through the drive
(towards the motor) in full kilowatt-hours. Whenever
the counter rolls over,
is
incremented. The minimum value is zero.
Inverter kWh
motoring
1.20
10 = 1 kWh / 1 = 1 kWh
Motoring energy in kWh.
0...1000 kWh
- / real32
Measured U-phase current.
U-phase current
1.21
- / -
U-phase current. For scaling, see parameter
-30000.00 ...
30000.00 A
- / real32
Measured V-phase current.
V-phase current
1.22
- / -
V-phase current. For scaling, see parameter
-30000.00 ...
30000.00 A
- / real32
Measured W-phase current.
W-phase current
1.23
- / -
W-phase current. For scaling, see parameter
-30000.00 ...
30000.00 A
- / real32
Used flux reference in percent of nominal flux of motor.
Flux actual %
1.24
1 = 1 % / 1 = 1 %
Flux reference.
0...200 %
Parameters 135
Summary of Contents for ACS880 N5700 Series
Page 1: ... ABB INDUSTRIAL DRIVES ACS880 position control program N5700 Firmware manual ...
Page 2: ......
Page 4: ......
Page 22: ...22 ...
Page 28: ...28 ...
Page 32: ...32 ...
Page 60: ...60 ...
Page 546: ...546 ...
Page 604: ...604 ...
Page 626: ...626 ...
Page 640: ...640 ...
Page 660: ...660 ...