Def / Type
FbEq 16b / 32b
Description
Name / Range /
Selection
No.
Values of references received from various sources.
Input references
3
All parameters in this group are read-only unless
otherwise noted.
0.00 / real32
Local reference given from the control panel or PC tool.
Panel reference
3.1
1 = 10 / 100 = 1
Local control panel or PC tool reference.
-100000.00 ...
100000.00
- / real32
Remote reference given from the control panel or PC
tool.
Panel reference 2
3.2
1 = 10 / 100 = 1
Remote control panel or PC tool reference.
-30000.00 ...
30000.00
0.00 / real32
Reference 1 received through fieldbus adapter A.
See also chapter
Fieldbus control through a fieldbus
.
FB A reference 1
3.5
1 = 10 / 100 = 1
Reference 1 from fieldbus adapter A.
-100000.00 ...
100000.00
0.00 / real32
Reference 2 received through fieldbus adapter A.
FB A reference 2
3.6
1 = 10 / 100 = 1
Reference 2 from fieldbus adapter A.
-100000.00 ...
100000.00
0.00 / real32
Reference 1 received through fieldbus adapter B.
FB B reference 1
3.7
1 = 10 / 100 = 1
Reference 1 from fieldbus adapter B.
-100000.00 ...
100000.00
0.00 / real32
Reference 2 received through fieldbus adapter B.
FB B reference 2
3.8
1 = 10 / 100 = 1
Reference 2 from fieldbus adapter B.
-100000.00 ...
100000.00
- / real32
Scaled reference 1 received through the embedded
fieldbus interface. The scaling is defined by
EFB reference 1
3.9
1 = 10 / 100 = 1
Reference 1 received through the embedded fieldbus
interface.
-30000.00 ...
30000.00
- / real32
Scaled reference 2 received through the embedded
fieldbus interface. The scaling is defined by
.
EFB reference 2
3.10
1 = 10 / 100 = 1
Reference 2 received through the embedded fieldbus
interface.
-30000.00 ...
30000.00
- / real32
Reference 1 received from the external (DDCS)
controller.
DDCS controller ref
1
3.11
The value has been scaled according to parameter
60.60 DDCS controller ref1 type
See also section
External controller interface (page 74)
1 = 10 / 100 = 1
Scaled reference 1 received from external controller.
-30000.00 ...
30000.00
- / real32
Reference 2 received from the external (DDCS)
controller.
DDCS controller ref
2
3.12
The value has been scaled according to parameter
140 Parameters
Summary of Contents for ACS880 N5700 Series
Page 1: ... ABB INDUSTRIAL DRIVES ACS880 position control program N5700 Firmware manual ...
Page 2: ......
Page 4: ......
Page 22: ...22 ...
Page 28: ...28 ...
Page 32: ...32 ...
Page 60: ...60 ...
Page 546: ...546 ...
Page 604: ...604 ...
Page 626: ...626 ...
Page 640: ...640 ...
Page 660: ...660 ...