Motor revs = motor-side revolutions before gear ratio
Load units = load-side distance in rotary or linear movement
■
Overview
The drawing below is an overview of the main items related to position feedback
scaling, depending on the location of the feedback device. The device can be
located on
•
(A) the motor shaft,
•
(B) the load shaft behind a gear, or
•
(C) the load side behind the mechanical transmission.
ENC 2
ENC 1
Position
control
86.14
86.15
Load gear
86.16
86.17
Feed constant
86.18
86.19
Modulo range
86.02 Actual position
88.01 Position reference used
60
Load gear x Feed constant
86.21
86.22
Load encoder scale
Speed
control
Motor gear
90.43
90.44
24.02 Used speed feedback
M
A
B
C
Feed unit = Load units / Load revs
Gear ratio = Motor revs / Load revs
Load units
Load revs
Motor revs
Position feedback
88.03 Speed reference positioning
Speed feedback
This table contains formulas for setting the actual position scaling in the three
configurations.
Load (C)
Load shaft (B)
Motor shaft (A)
Feedback
Linear (rotary) en-
coder
Rotary encoder
Rotary encoder
1
1
1/Gear ratio
Load gear
Load units/Load en-
coder revs
Load units/Load revs
Load units/Load revs
Feed constant
0
1 *
Gear ratio *
Modulo range
Position control program features 41
Summary of Contents for ACS880 N5700 Series
Page 1: ... ABB INDUSTRIAL DRIVES ACS880 position control program N5700 Firmware manual ...
Page 2: ......
Page 4: ......
Page 22: ...22 ...
Page 28: ...28 ...
Page 32: ...32 ...
Page 60: ...60 ...
Page 546: ...546 ...
Page 604: ...604 ...
Page 626: ...626 ...
Page 640: ...640 ...
Page 660: ...660 ...