Position CW reset
30
Control word bit 7 received through fieldbus interface
A.
FBA A MCW bit 7
32
Control word bit 7 received through the embedded
fieldbus interface.
EFB MCW bit 7
See
Terms and abbreviations (page 130)
Other [bit]
- / uint16
Selects faults that are automatically reset. The
parameter is a 16-bit word with each bit corresponding
to a fault type.
Whenever a bit is set to 1, the corresponding fault is
automatically reset.
The number and interval of reset attempts are defined
by parameters
…
.
WARNING!
Before you activate the function, make sure that
no dangerous situations can occur. The function
resets the drive automatically and continues
operation after a fault.
Note:
•
The autoreset function is only available in external
control; see section
.
•
Faults related to the Safe torque off (STO)
function cannot be automatically reset.
The bits of this binary number correspond to the
following faults:
Autoreset selection
31.12
Overcurrent
b0
Overvoltage
b1
Undervoltage
b2
AI supervision fault
b3
Supply unit
b4
Reserved
b5…7
Defined in the application program
Application fault 1
b8
Defined in the application program
Application fault 2
b9
See parameter
Selectable fault
b10
From source selected by parameter
External fault 1
b11
From source selected by parameter
External fault 2
b12
From source selected by parameter
External fault 3
b13
318 Parameters
Summary of Contents for ACS880 N5700 Series
Page 1: ... ABB INDUSTRIAL DRIVES ACS880 position control program N5700 Firmware manual ...
Page 2: ......
Page 4: ......
Page 22: ...22 ...
Page 28: ...28 ...
Page 32: ...32 ...
Page 60: ...60 ...
Page 546: ...546 ...
Page 604: ...604 ...
Page 626: ...626 ...
Page 640: ...640 ...
Page 660: ...660 ...