Def / Type
FbEq 16b / 32b
Description
Name / Range /
Selection
No.
3
Adapter configuration error: mapping file not found in
the file system of the drive, or mapping file upload has
failed more than three times.
Configuration error
4
Fieldbus communication is off-line.
Off-line
5
Fieldbus communication is on-line, or fieldbus adapter
has been configured not to detect a communication
break. For more information, see the documentation
of the fieldbus adapter.
On-line
6
Adapter is performing a hardware reset.
Reset
0 / uint16
Displays the patch and build versions of the adapter
module firmware in format xxyy, where xx = patch
version number, yy = build version number.
Example: C802 = 200.02 (patch version 200, build
version 2).
FBA A comm SW ver
51.32
1 = 1
Patch and build versions of adapter module firmware.
0000…FFFFh
0 / uint16
Displays the major and minor versions of the adapter
module firmware in format xyy, where x = major revision
number, yy = minor revision number.
Example: 300 = 3.00 (major version 3, minor version
00).
FBA A appl SW ver
51.33
1 = 1
Major and minor versions of adapter module firmware.
0000…FFFFh
Parameters 389