Def / Type
FbEq 16b / 32b
Description
Name / Range /
Selection
No.
1000 = 1 units/s^2 /
1 = 1 units/s^2
Deceleration
0.000 ...
20000000.000
units/s^2
0.000 units/s^3 /
real32
Defines the jerk value for positioning index 1.
Pos index 1 jerk
76.15
1000 = 1 units/s^3 /
1 = 1 units/s^3
Jerk value.
0.000 ...
20000000.000
units/s^3
0.000 units/s / real32
Defines the end velocity for positioning index 1.
Pos index 1 end
velocity
76.16
1000 = 1 units/s / 1 =
1 units/s
End velocity
0.000 ...
2000000.000
units/s
- / uint16
Defines the type and direction of movement for
positioning index 2.
See
Pos index 2 mode
76.20
0.000 units / real32
Depending on bit 1 of
, defines either the absolute
target position, or the distance from the last reference
position.
See
76.11 Pos index 1 target position
.
Pos index 2 target
position
76.21
1000 = 1 units / 1 = 1
units
-2000000.000 ...
2000000.000 units
…
…
…
…
0.000 units/s / real32
Defines the end velocity for positioning index 8.
See
76.16 Pos index 1 end velocity
Pos index 8 end
velocity
76.86
1000 = 1 units/s / 1 =
1 units/s
0.000 ...
2000000.000
units/s
Parameters 459