126 Parameters
Const
Bit pointer setting (see
on page
-
Pointer
10.04
Ext2 start func
Selects the source of start and stop commands for external
control location 2 (EXT2).
Note:
This parameter cannot be changed while the drive is
running.
Not sel
No start or stop command sources selected.
0
In1
The source of the start and stop commands is selected by
parameter
. The state transitions of the
source bit are interpreted as follows:
1
3-wire
The sources of the start and stop commands is selected by
parameters
state transitions of the source bits are interpreted as follows:
2
FB
The start and stop commands are taken from the fieldbus
Control Word which is defined by parameter
3
D2D
The start and stop commands are taken from another drive
through the D2D (Drive-to-drive) Control Word.
4
In1F In2R
The source selected by
is the forward
start signal, the source selected by
reverse start signal.
5
In1St In2Dir
is the start signal
(0 = stop, 1 = start), the source selected by
is the direction signal (0 = forward, 1 = reverse).
6
10.05
Ext2 start in1
Selects source 1 of start and stop commands for external
control location EXT2. See parameter
selections
and
Note:
This parameter cannot be changed while the drive is
running.
DI1
Digital input DI1 (as indicated by
1073742337
DI6
Digital input DI6 (as indicated by
1074070017
DIO4
Digital input/output DIO4 (as indicated by
,
bit 3).
1073938947
No.
Name/Value
Description
FbEq
State of source
(via par
Command
0 -> 1
Start
1 -> 0
Stop
)
)
Command
0 -> 1
1
Start
Any
1 -> 0
Stop
Any
0
Stop
)
)
Command
0
0
Stop
1
0
Start forward
0
1
Start reverse
1
1
Stop
Summary of Contents for ACS850 series
Page 1: ...ACS850 Firmware Manual ACS850 Standard Control Program ...
Page 4: ......
Page 56: ...56 Control locations and operating modes ...
Page 262: ...262 Parameters ...
Page 310: ...310 Fault tracing ...
Page 348: ...348 Control through a fieldbus adapter ...
Page 358: ...358 Drive to drive link ...