Fault tracing 301
Extension: 2
The ID run cannot be
completed because the
maximum speed setting and/or
calculated field weakening
point is too low.
Check setting of parameters
,
and
that
•
> (0.55 ×
) > (0.50 × synchronous
speed),
•
< 0, and
• supply voltage > (0.66 ×
).
Extension: 3
The ID run cannot be
completed because the
maximum torque setting is too
low.
Check setting of parameter
and torque limits defined in
parameter group
that the active maximum torque (selected
by
) > 100%.
Extension: 4
Current measurement
calibration did not finish within
reasonable time.
Contact your local ABB representative.
Extension: 5…8
Internal error.
Contact your local ABB representative.
Extension: 9
Asynchronous motors only:
Acceleration did not finish
within reasonable time.
Contact your local ABB representative.
Extension: 10
Asynchronous motors only:
Deceleration did not finish
within reasonable time.
Contact your local ABB representative.
Extension: 11
Asynchronous motors only:
Speed dropped to zero during
ID run.
Contact your local ABB representative.
Extension: 12
Permanent magnet motors
only: First acceleration did not
finish within reasonable time.
Contact your local ABB representative.
Extension: 13
Permanent magnet motors
only: Second acceleration did
not finish within reasonable
time.
Contact your local ABB representative.
Extension: 14…16
Internal error.
Contact your local ABB representative.
0018
CURR U2 MEAS
(0x3184)
Measured offset error of U2
output phase current
measurement is too great.
(Offset value is updated during
current calibration.)
Contact your local ABB representative.
0019
CURR V2 MEAS
(0x3185)
Measured offset error of V2
output phase current
measurement is too great.
(Offset value is updated during
current calibration.)
Contact your local ABB representative.
0020
CURR W2 MEAS
(0x3186)
Measured offset error of W2
output phase current
measurement is too great.
(Offset value is updated during
current calibration.)
Contact your local ABB representative.
Code
Fault
(fieldbus code)
Cause
What to do
Summary of Contents for ACS850 series
Page 1: ...ACS850 Firmware Manual ACS850 Standard Control Program ...
Page 4: ......
Page 56: ...56 Control locations and operating modes ...
Page 262: ...262 Parameters ...
Page 310: ...310 Fault tracing ...
Page 348: ...348 Control through a fieldbus adapter ...
Page 358: ...358 Drive to drive link ...