Additional parameter data 265
When a value pointer parameter is connected to an application program, the format is
as follows:
Note:
Value pointer parameters connected to an application program are read-only
via fieldbus.
32-bit integer bit pointers
When a bit pointer parameter is connected to value 0 or 1, the format is as follows:
When a bit pointer parameter is connected to a bit value of another parameter, the
format is as follows:
When a bit pointer parameter is connected to an application program, the format is as
follows:
Bit
30…31
24…29
0…23
Name
Source type
Not in use
Address
Value
2
-
0 … 2
24
-1
Description
Value pointer is
connected to
application program.
-
Relative address of
application program
variable
Bit
30…31
16…29
1…15
0
Name
Source type
Not in use
Not in use
Value
Value
0
-
-
0…1
Description
Bit pointer is
connected to 0/1.
-
-
0 = False, 1 = True
Bit
30…31
24…29
16…23
8…15
0…7
Name
Source type
Not in use
Bit sel
Group
Index
Value
1
-
0…31
2…255
1…255
Description
Bit pointer is
connected to
signal bit
value.
-
Bit selection
Group of
source
parameter
Index of
source
parameter
Bit
30…31
24…29
0…23
Name
Source type
Bit sel
Address
Value
2
0…31
0 … 2
24
-1
Summary of Contents for ACS850 series
Page 1: ...ACS850 Firmware Manual ACS850 Standard Control Program ...
Page 4: ......
Page 56: ...56 Control locations and operating modes ...
Page 262: ...262 Parameters ...
Page 310: ...310 Fault tracing ...
Page 348: ...348 Control through a fieldbus adapter ...
Page 358: ...358 Drive to drive link ...