234 Parameters
Torque
Fieldbus uses torque reference scaling. Torque reference
scaling is defined by the used fieldbus profile (e.g. with ABB
Drives Profile integer value 10000 corresponds to 100%
torque value). Signal
is sent to the
fieldbus as an actual value. See the
User’s Manual
of the
appropriate fieldbus adapter module.
1
Speed
Fieldbus uses speed reference scaling. Speed reference
scaling is defined by the used fieldbus profile (e.g. with ABB
Drives Profile integer value 20000 corresponds to parameter
value). Signal
is
sent to the fieldbus as an actual value. See the
User’s Manual
of the appropriate fieldbus adapter module.
2
50.05
Fb ref2 modesel
Selects the fieldbus reference FBA REF2 scaling.
See parameter
.
Raw data
See parameter
.
0
Torque
See parameter
.
1
Speed
See parameter
.
2
50.06
Fb act1 tr src
Selects the source for fieldbus actual value 1 when parameter
is set to
.
Pointer
Value pointer setting (see
on page
-
50.07
Fb act2 tr src
Selects the source for fieldbus actual value 2 when parameter
is set to
.
Pointer
Value pointer setting (see
on page
-
50.08
Fb sw b12 src
Selects the source for freely programmable fieldbus status
word bit 28 (
bit 28). Note that this
functionality may not be supported by the fieldbus
communication profile.
Const
Bit pointer setting (see
on page
-
Pointer
50.09
Fb sw b13 src
Selects the source for freely programmable fieldbus status
word bit 29 (
bit 29). Note that this
functionality may not be supported by the fieldbus
communication profile.
Const
Bit pointer setting (see
on page
-
Pointer
50.10
Fb sw b14 src
Selects the source for freely programmable fieldbus status
word bit 30 (
bit 30). Note that this
functionality may not be supported by the fieldbus
communication profile.
Const
Bit pointer setting (see
on page
-
Pointer
50.11
Fb sw b15 src
Selects the source for freely programmable fieldbus status
word bit 31 (
bit 31). Note that this
functionality may not be supported by the fieldbus
communication profile.
Const
Bit pointer setting (see
on page
-
Pointer
No.
Name/Value
Description
FbEq
Summary of Contents for ACS850 series
Page 1: ...ACS850 Firmware Manual ACS850 Standard Control Program ...
Page 4: ......
Page 56: ...56 Control locations and operating modes ...
Page 262: ...262 Parameters ...
Page 310: ...310 Fault tracing ...
Page 348: ...348 Control through a fieldbus adapter ...
Page 358: ...358 Drive to drive link ...