256 Parameters
97.20
PM angle offset
Defines an angle offset between the zero position of the
synchronous motor and the zero position of the position
sensor.
Notes:
• The value is in electrical degrees. The electrical angle
equals the mechanical angle multiplied by the number of
motor pole pairs.
• This parameter is valid only for permanent magnet motors.
0…360°
Angle offset.
1 = 1°
99
99 Start-up data
Language selection, motor configuration and ID run settings.
99.01
Language
Selects the language of the control panel displays.
Note:
Not all languages listed below are necessarily
supported.
English
English.
0809 hex
Deutsch
German.
0407 hex
Italiano
Italian.
0410 hex
Español
Spanish.
040A hex
Nederlands
Dutch.
0413 hex
Français
French.
040C hex
Dansk
Danish.
0406 hex
Svenska
Swedish.
041D hex
Russki
Russian.
0419 hex
Polski
Polish.
0415 hex
Türkçe
Turkish.
041F hex
Chinese
Chinese.
0804 hex
Serbian
Serbian.
081A hex
99.04
Motor type
Selects the motor type.
Note:
This parameter cannot be changed while the drive is
running.
AM
Asynchronous motor. Three-phase AC induction motor with
squirrel cage rotor.
0
PMSM
Permanent magnet motor. Three-phase AC synchronous
motor with permanent magnet rotor and sinusoidal BackEMF
voltage.
1
SynRM
Synchronous reluctance motor. Three-phase AC
synchronous motor with salient pole rotor without permanent
magnets.
2
No.
Name/Value
Description
FbEq
Summary of Contents for ACS850 series
Page 1: ...ACS850 Firmware Manual ACS850 Standard Control Program ...
Page 4: ......
Page 56: ...56 Control locations and operating modes ...
Page 262: ...262 Parameters ...
Page 310: ...310 Fault tracing ...
Page 348: ...348 Control through a fieldbus adapter ...
Page 358: ...358 Drive to drive link ...