Chapter 43 Access Control
GS2210 Series User’s Guide
376
t ransceiver- ddm
zy Transceiver Ddm iTem perat ur
eOut OfRange
1.3.6.1.4.1.890.1.15.3.84.3.1
This t rap is sent w hen t he
t ransceiver t em perat ur e is above or
below t he nor m al operat ing range.
zy Transceiver Ddm iTx Pow er Out
OfRange
1.3.6.1.4.1.890.1.15.3.84.3.2
This t rap is sent w hen t he
t ransm it t ed opt ical pow er is above
or below t he nor m al operat ing
range.
zy Transceiver Ddm iRx Pow er Out
OfRange
1.3.6.1.4.1.890.1.15.3.84.3.3
This t rap is sent w hen t he r eceived
opt ical pow er is above or below t he
nor m al operat ing range.
zy Transceiver Ddm iVolt ageOut
OfRange
1.3.6.1.4.1.890.1.15.3.84.3.4
This t rap is sent w hen t he
t ransceiver supply volt age is above
or below t he nor m al operat ing
range.
zy Transceiver Ddm iTx BiasOut Of
Range
1.3.6.1.4.1.890.1.15.3.84.3.5
This t rap is sent w hen t he
t ransm it t er laser bias cur r ent is
above or below t he nor m al
operat ing range.
zy Transceiver Ddm iTem perat ur
eOut OfRangeRecover ed
1.3.6.1.4.1.890.1.15.3.84.3.6
This t rap is sent w hen t he
t ransceiver t em perat ur e is
r ecover ed fr om t he out of nor m al
operat ing range.
zy Transceiver Ddm iTx Pow er Out
OfRangeRecover ed
1.3.6.1.4.1.890.1.15.3.84.3.7
This t rap is sent w hen t he
t ransm it t ed opt ical pow er is
r ecover ed fr om t he out of nor m al
operat ing range.
zy Transceiver Ddm iRx Pow er Out
OfRangeRecover ed
1.3.6.1.4.1.890.1.15.3.84.3.8
This t rap is sent w hen t he r eceived
opt ical pow er is r ecover ed fr om t he
out of nor m al operat ing range.
zy Transceiver Ddm iVolt ageOut
OfRangeRecover ed
1.3.6.1.4.1.890.1.15.3.84.3.9
This t rap is sent w hen t he
t ransceiver supply volt age is
r ecover ed fr om t he out of nor m al
operat ing range.
zy Transceiver Ddm iTx BiasOut Of
RangeRecovered
1.3.6.1.4.1.890.1.15.3.84.3.10
This t rap is sent w hen t he
t ransm it t er laser bias cur r ent is
r ecover ed fr om t he out of nor m al
operat ing range.
St or m - cont r ol
zy Por t St or m Cont r olTrap
1.3.6.1.4.1.890.1.15.3.78.2.1
This t rap is sent w hen st or m cont r ol
is det ect ed on a specific por t . A
packet filt er act ion has been applied
on t he int er face.
zuld
zy ZuldUnidir ect ionalDet ect ed
1.3.6.1.4.1.890.1.15.3.110.3.1
This t rap is sent w hen a
unidir ect ional link is det ect ed.
zy ZuldBidir ect ionalRecover ed
1.3.6.1.4.1.890.1.15.3.110.3.2
This t rap is sent w hen t he por t
w hich is shut dow n by ZULD
becom es act ive again.
Table 190
SNMP I nt er face Tr aps ( cont inued)
OPTION
OBJECT LABEL
OBJECT ID
DESCRIPTION
Содержание GS2210-24
Страница 18: ...18 PART I User s Guide ...
Страница 33: ...33 PART II Technical Reference ...
Страница 110: ...Chapter 9 VLAN GS2210 Series User s Guide 110 Figure 83 Advanced Application VLAN Port Based VLAN Setup All Connected ...
Страница 111: ...Chapter 9 VLAN GS2210 Series User s Guide 111 Figure 84 Advanced Application VLAN Port Based VLAN Setup Port Isolation ...
Страница 178: ...Chapter 21 Classifier GS2210 Series User s Guide 178 Figure 127 Classifier Example ...
Страница 405: ...Chapter 51 Configure Clone GS2210 Series User s Guide 405 Figure 286 Management Configure Clone ...
Страница 433: ...Appendix D Legal Information GS2210 Series User s Guide 433 Environmental Product Declaration ...