11. Pull the tank bracket rearward until the tank is
free of the damper (A,
Figure 7
) on each side of the
frame. Remove the fuel tank.
12. Installation is the reverse of removal. Note the
following:
a. Set the tank on the frame and route the meter
assembly cable and hoses along the paths
noted during removal.
b. Slide the tank forward until the tank engages
the damper (A,
Figure 7
) on each side of the
frame.
c. Route the meter connector beneath the ignitor
panel.
d. Torque the fuel tank bolts to 23 N•m (17
ft.-lb.).
e. Insert the meter connector (B,
Figure 5
) be-
neath the ignitor panel.
d. Secure the harness and hoses with any cable
holders released during removal.
FUEL VALVE
Removal/Installation
WARNING
Some fuel may spill during the follow
ing procedure. Work in a well venti
lated area at least 50 feet from any
sparks or flames, including gas appli
ance pilot lights. Do not allow any
smoking in the area. Keep a B:C rated
fire extinguisher on hand.
Refer to
Figure 8
.
1. Remove the fuel tank as described in this chap-
ter.
2. Set the fuel tank on a protective pad or blanket.
AIR/FUEL, EXHAUST AND EMISSION CONTROL SYSTEMS
205
8
3
4
5
6
7