ProAct P-Series FL Position Controller
Manual 26659
22
Woodward
The output range is set with JPR1. Position “A” is for (0 to 5) V (dc) and position
“B” is for (4 to 20) mA. The jumper changes both the hardware connection and
software scaling.
Take care to avoid shorting TB1 to battery voltage, as this could
damage the circuit [if configured in the (0 to 5) V (dc) range].
The default scaling for the analog output ranges is identified in the table below.
Analog Output function and scaling can be modified using the Service Tool.
Range
Min (0 %)
Max (100 %)
(0 to 5) V (dc)
0.5 V (dc)
4.5 V (dc)
(4 to 20) mA
4 mA
20 mA
When jumpers are set for the (0 to 5) V (dc) Analog Output Range,
shorting 24 V power (+) to TB 1 (Analog ) could damage the
circuit.
A shielded twisted-pair cable is recommended for the analog output. The output
can be setup in the software for scaling and output type.
It is possible to use the analog output, in (4 to 20) mA range, with more than one
load if the
total
load resistance is not greater than 450
Ω
.
CAN Port
17
15
ProAct Integrated Speed Control .
Analog Input.
CAN
Controller.
16
ProAct
CAN interface
120
Ω
User Control
120
Ω
CA N High.
CA N Low.
CA N Common
9
TB 17 = CAN High
TB 15 = CAN Low
TB 16 = Shield
The CAN (Control Area Network) communication link is used for supervisory
control and monitoring of the actuator position using a J1939 protocol. The
CANbus is available for monitoring at any time independent of software
configuration. However, control functions over CAN are only permitted when a
CAN position command is configured.
The use of CANbus cable that meets SAE J1939-11 specifications for impedance
and shielding properties is required for CAN communication usage. The battery
minus signal and the shield signal are not connected and therefore the shield
cannot be used as a common signal between the controls.
Содержание ProAct P Series FL
Страница 10: ...ProAct P Series FL Position Controller Manual 26659 viii Woodward ...
Страница 15: ...Manual 26659 ProAct P Series FL Position Controller Woodward 5 Figure 1 1 ProAct P Series FL Outline Drawing ...
Страница 23: ...Manual 26659 ProAct P Series FL Position Controller Woodward 13 Figure 2 2a Actuator Wiring Diagram ...
Страница 24: ...ProAct P Series FL Position Controller Manual 26659 14 Woodward Figure 2 2b Actuator Wiring Diagram Notes ...
Страница 79: ...Manual 26659 ProAct P Series FL Position Controller Woodward 69 Figure 6 8 Strip Chart Properties Window ...
Страница 108: ...ProAct P Series FL Position Controller Manual 26659 98 Woodward Declarations ...
Страница 109: ...Manual 26659 ProAct P Series FL Position Controller Woodward 99 ...