Manual 26659
ProAct P-Series FL Position Controller
Woodward
3
The P-Series FL replaces the circular connector with terminal blocks to allow a
shorter overall actuator length and provide flexibility in wiring, as only the needed
wires are hooked up. The wiring (provided by the customer) exits the side of the
actuator through an M12 and/or M16 threaded port(s) using cable glands or
conduit. Note that there is not space for all connections, so if all wiring is needed,
it is necessary to use the ProAct P-Series FL with the circular connector.
Programmable Features
Actuator setup and tuning is accomplished through the use of a PC (personal
computer), Woodward Service Tool software, and a programming harness. The
features identified below are described in Chapters 2 and 4. Briefly, the
programmable features include:
General
Setup
o
Direction (CCW or CW)
o Fail
Position
Position
Controller
o
Dynamics (friction & inertia)
o
Position Error magnitude & delay
o Non-Linear
actuator
settings
Position
Demand
o
Position Demand Select (Primary/Backup; CAN, PWM or Analog)
o Tracking
options
PWM Input scaling, failure levels, offset
Analog Input scaling and failure levels
Analog Output selection & scaling
Discrete Output Settings
o
Output’s Non-Fault Condition (ON or OFF)
o
Fault Selections as Discrete Output Indications
Fault
Settings
o
Latching or Non-Latching Fault Indications
o
Fault Selections as Alarms or Shutdowns
CAN
(J1939)
o
CAN Data Rate
o
CAN ID input selections
o
Demand Failure Timeout
o
Data PGN, Command PGN, Source address, Function Field
Service Tool Software
The ProAct P-Series FL Service Tool software is a Microsoft Windows based
GUI (graphic user interface). The Service Tool Software is compatible with
Windows 2000, XP, Vista, 7 (32- and 64-bit) or greater and provides the ability to:
Configure product settings based on application requirements
Tune the actuator with the engine running during application development
Create configuration files for downloading into multiple controls
Download configuration files
Extract and view fault codes for field diagnosis
Update actuator dynamics during field service
Calibrate the actuator for user stops
Detailed descriptions of software installation are available in Chapter 4.
Содержание ProAct P Series FL
Страница 10: ...ProAct P Series FL Position Controller Manual 26659 viii Woodward ...
Страница 15: ...Manual 26659 ProAct P Series FL Position Controller Woodward 5 Figure 1 1 ProAct P Series FL Outline Drawing ...
Страница 23: ...Manual 26659 ProAct P Series FL Position Controller Woodward 13 Figure 2 2a Actuator Wiring Diagram ...
Страница 24: ...ProAct P Series FL Position Controller Manual 26659 14 Woodward Figure 2 2b Actuator Wiring Diagram Notes ...
Страница 79: ...Manual 26659 ProAct P Series FL Position Controller Woodward 69 Figure 6 8 Strip Chart Properties Window ...
Страница 108: ...ProAct P Series FL Position Controller Manual 26659 98 Woodward Declarations ...
Страница 109: ...Manual 26659 ProAct P Series FL Position Controller Woodward 99 ...