Chapter 3 Initialization and Calibration
87
Adjusting AutoSetPAC To Read the Correct Tonnage
To adjust the tonnage displayed in AutoSetPAC so it agrees with the value(s) shown on the
calibration unit, perform the following steps:
1.
Select CALIBRATION on the Tonnage/Waveform Initialization Menu to display the Calibration
screen (see Figure 3-22).
Figure 3-22.
Calibration Screen
2.
Familiarize yourself with the gain adjustment potentiometers and high/low gain jumpers to the
left of the strain link inputs at the bottom of the AutoSetPAC processor board (see Figure 2-6 or
Figure 2-7). Table 3-5 shows the processor board labels that identify potentiometers and jumpers
for each AutoSetPAC model.
Содержание AutoSet PAC 120 VAC
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 12: ...12 Table of Contents ...
Страница 14: ...14 ...
Страница 16: ...16 ...
Страница 18: ...18 ...
Страница 28: ...1101600 AutoSetPAC User Manual 28 Chapter 1 Installation ...
Страница 106: ...1101600 AutoSetPAC User Manual 106 Chapter 4 Using AutoSetPAC in Program Mode ...
Страница 122: ...1101600 AutoSetPAC User Manual 122 Chapter 5 Using AutoSetPAC in Run Mode Figure 5 18 Tool Loading Message ...
Страница 133: ......
Страница 134: ......
Страница 135: ......
Страница 136: ......
Страница 137: ......
Страница 138: ......
Страница 139: ......
Страница 140: ......
Страница 141: ......
Страница 142: ......
Страница 143: ......
Страница 144: ......
Страница 145: ......
Страница 146: ......
Страница 147: ......
Страница 148: ......
Страница 149: ......
Страница 150: ......
Страница 151: ......
Страница 152: ......
Страница 153: ......
Страница 154: ......
Страница 155: ......
Страница 156: ......