
1101600
AutoSetPAC User Manual
132
Index
oscilloscope, wiring, 51
P
panel mount, installing, 32
processor board (24 Vdc)
installing, 35
mounting dimensions, 35
processor board (no enclosure), installing, 34
processor board, location of components
AutoSet 2-Channel calibration kit (new style), 80
AutoSet 2-Channel calibration kit (old style), 79
AutoSet 2-Channel calibration kit (V2.0 board), 81
AutoSetPAC 2-Channel, 37
AutoSetPAC 4-Channel, 36, 38
R
recalculating setpoints, 104, 114, 119
repeatability setpoints
viewing/adjusting in Program mode, 103
viewing/adjusting in Run mode, 113
reverse tonnage
establishing a setpoint percentage and calculating
setpoints, 68
viewing, 120
Run mode, locking out functions, 69
S
sample period
setting number of strokes, 99
viewing/adjusting in Run mode, 114
security, 69
setpoint percentage
setting high setpoint %, 99
setting low setpoint %, 99
setting repeatability setpoint %, 99
setting reverse setpoint %, 68
setpoints
adjusting in Program mode, 101
adjusting in Run mode, 112
enabling/disabling, 68
how AutoSetPAC calculates, 93
programming setpoint percentages, 99
recalculating in Program mode, 104
recalculating in Run mode, 114, 119
viewing in Program mode, 101
viewing in Run mode, 110, 112
setup mode, enabling/disabling, 68
shield (cable), terminating, 46, 51
SmartPAC
connecting an AutoSet to, 54
SmartPAC PRO
front panel, 23
specifications, 27
startup counter
enabling/disabling, 68
setting number of strokes, 99
stop circuits, wiring, 36
strain links
changing default input names, 66
models available from Wintriss, 41
mounting, 42
using a voltmeter to zero, 76
wiring, 46
zeroing, 73
switches. See Mode switches (S101), 61
T
tension
mounting strain links to measure, 43, 44
strain link wiring connections for, 47
tonnage
viewing current (Program mode), 102
viewing current (Run mode), 109, 110, 112
viewing history, 115
tonnage display formats
AutoSet 2-Channel calibration kit, 83
AutoSetPAC, 86
tonnage history
clearing, 119
viewing, 115
tonnage monitor program settings
changing, 101
copying from one tool to another, 100
entering, 98
loading, 99
tool, loading new, 121
troubleshooting, 127
W
wiring connections
AC power, 40
communications, 50
oscilloscope, 52
stop circuit, 40
strain links, 47
zero cam, 48
Z
zero cam
connecting wiring from SmartPAC 2 or SmartPAC
PRO, 48
verifying signal closure at top of stroke by checking
LED, 128
Содержание AutoSet PAC 120 VAC
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 12: ...12 Table of Contents ...
Страница 14: ...14 ...
Страница 16: ...16 ...
Страница 18: ...18 ...
Страница 28: ...1101600 AutoSetPAC User Manual 28 Chapter 1 Installation ...
Страница 106: ...1101600 AutoSetPAC User Manual 106 Chapter 4 Using AutoSetPAC in Program Mode ...
Страница 122: ...1101600 AutoSetPAC User Manual 122 Chapter 5 Using AutoSetPAC in Run Mode Figure 5 18 Tool Loading Message ...
Страница 133: ......
Страница 134: ......
Страница 135: ......
Страница 136: ......
Страница 137: ......
Страница 138: ......
Страница 139: ......
Страница 140: ......
Страница 141: ......
Страница 142: ......
Страница 143: ......
Страница 144: ......
Страница 145: ......
Страница 146: ......
Страница 147: ......
Страница 148: ......
Страница 149: ......
Страница 150: ......
Страница 151: ......
Страница 152: ......
Страница 153: ......
Страница 154: ......
Страница 155: ......
Страница 156: ......