1101600
AutoSetPAC User Manual
76
Chapter 3 Initialization and Calibration
15.
If you cannot adjust the strain link’s offset reading to within the ±50 window, loosen the
mounting screws and repeat steps 12 through 14.
NOTICE
If after several attempts you cannot get the Zero Offsets display to read in the ±50 range, the
strain link mounting holes may not have been drilled at right angles to the mounting surface, or
the strain link may not be working properly. Contact Wintriss Tech. Support for assistance.
16.
Replace the strain link cover, if necessary, when you have finished zeroing the strain link.
NOTICE
When multiple strain links have zero offsets readings outside the ±99 window, an Offsets Error
message will display for only one strain link channel at a time. When that strain link has been
adjusted to a value within the ±99 window, an Offsets Error message will display for one of the
remaining out-of-range strain links.
17.
Zero the remaining strain links, repeating steps 7 through 16. Start with any strain link that is
generating an Offsets Error message on the Current Zero Offsets display. When no strain link is
generating an Offsets Error message, proceed with zeroing the strain links that remain.
18.
When all the strain links have been zeroed, press RESET or EXIT repeatedly to return to the
SmartPAC Main Initialization Menu.
Using a Voltmeter to Zero Strain Links
Perform the following procedure if the AutoSetPAC Zero Offsets display cannot be used to zero
strain links (i.e., display is too far away or is obstructed).
1.
On the AutoSetPAC processor board, place the leads of a voltage meter on the pins holding the
white and green wires (i.e., pins 2 and 3) in the cable from the strain link you are having trouble
zeroing.
2.
Adjust the potentiometer screw on that strain link until the reading shown on the voltmeter is
close to 0Vdc.
NOTICE
The displayed voltage does not have to be exactly 0 Vdc. If the reading on the voltmeter is
b 0.70 and - 0.70 Vdc, the strain link can be considered zeroed.
3.
Check the Zero Offsets display. If it reads b50 and -50, you are finished.
If the Zero Offsets display continues to show a value outside this range, the strain link is bad and
should be replaced. Contact Wintriss Tech. Support for assistance.
Содержание AutoSet PAC 120 VAC
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 12: ...12 Table of Contents ...
Страница 14: ...14 ...
Страница 16: ...16 ...
Страница 18: ...18 ...
Страница 28: ...1101600 AutoSetPAC User Manual 28 Chapter 1 Installation ...
Страница 106: ...1101600 AutoSetPAC User Manual 106 Chapter 4 Using AutoSetPAC in Program Mode ...
Страница 122: ...1101600 AutoSetPAC User Manual 122 Chapter 5 Using AutoSetPAC in Run Mode Figure 5 18 Tool Loading Message ...
Страница 133: ......
Страница 134: ......
Страница 135: ......
Страница 136: ......
Страница 137: ......
Страница 138: ......
Страница 139: ......
Страница 140: ......
Страница 141: ......
Страница 142: ......
Страница 143: ......
Страница 144: ......
Страница 145: ......
Страница 146: ......
Страница 147: ......
Страница 148: ......
Страница 149: ......
Страница 150: ......
Страница 151: ......
Страница 152: ......
Страница 153: ......
Страница 154: ......
Страница 155: ......
Страница 156: ......