WF30T
Case Former
Troubleshooting & Repairs
- 10-105 -
Table 54: Jaw too slow; forming head speed normal
Problem
Possible Cause
Solution
Adjust the regulator’s set point.
Mast cylinder: 70 PSI.
Low Air Pressure
Regulator set point too low
Air pressure at machine’s main
regulator: 90 PSI.
Auto drain of the filter is not
working; water accumulated in
the cup is not discharged
Drain the water in the filter cup
and fix the auto drain valve or
replace the filter cup.
Water
Condensation
Too much water in the air
supply
Dry the air before it enters the
machine.
Overheating /
Too cold
Usually caused by high / low
ambient temperature
When ambient temperature is
over 60° or below 0° centigrade.
Table 55: Forming head not moving
Problem
Possible Cause
Solution
Compressed
air not
connected
Connect air supply.
Mechanical
Jam
Clear mechanical jam.
Socket loose
Tighten socket.
Open Circuit
Cable broken
Replace cable.
Overheating /
Too cold
Usually caused by high / low
ambient temperature
When ambient temperature is over
40° or below 0° centigrade.
Auto drain of the filter is not
working; water accumulated in
the cup is not discharged
Drain the water in the filter cup and
fix the auto drain valve or replace
the filter cup.
Water
Condensation
Too much water in the
air supply
Dry the air before it enters the
machine.
Содержание WF30T
Страница 2: ...WF30T Case Former ...
Страница 139: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 126 ...
Страница 140: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 127 ...
Страница 141: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 128 ...
Страница 142: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 129 ...
Страница 143: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 130 ...
Страница 144: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 131 ...
Страница 146: ...WF30T Case Former Appendix B MSDS Keystone Nevastane HT 2 133 ...
Страница 147: ...WF30T Case Former Appendix B MSDS Keystone Nevastane HT 2 134 ...
Страница 148: ...WF30T Case Former Appendix B MSDS Keystone Nevastane HT 2 135 ...
Страница 149: ...WF30T Case Former Appendix B MSDS Keystone Nevastane HT 2 136 ...
Страница 150: ...WF30T Case Former Appendix B MSDS Keystone Nevastane HT 2 137 ...