6.2 Start-up
6.2.1 Preliminary Checks
Before placing the WEXXAR Model WF30T Case Former into operation, check the following
points:
•
Is the machine set correctly for the case size? Scales showing the required settings are
located on the machine, and provide an easy quick check. If adjustments are required,
please refer to Section 7:
of this manual.
•
Is the magazine properly loaded with cases, and is the first case pushed down into the
caliper slot? See Section 6.3.2:
•
Is sufficient air pressure available? Verify that the gauge reads 90 PSI on the main
regulator and 70 PSI on both the Mast Regulator and the Jaw Regulator. The manual
shutoff valve must be
OPEN
.
•
Are all guards properly closed, and all personnel clear?
•
Is the electrical power disconnect switch turned
ON
? The Black operating lever should
be in a vertical position. Are all
‘EMERGENCY STOP’
buttons, including auxiliary
‘EMERGENCY STOP’
buttons, in the
OUT
position? Turn clockwise or pull out to
release.
•
Is the tape applicator on the WF30T properly installed, loaded with a tape roll, and ready
to go? The end of the tape should be on the front roller, with the sticky side facing the
incoming case. For complete tape installation instructions, see the separate Dekka Tape
Head Manual that is supplied with this machine. If your machine came with a non-
standard tape head, refer to the appropriate tape head manual.
•
Is
the
‘REMOTE DEMAND’
sensor clear? The machine will only form cases if this
sensor is clear, or if the
‘REMOTE DEMAND’
button on the touchscreen is turned to
OFF
.
•
Does the touchscreen display the desired mode of operation? The normal mode of
operation allows
CYCLE
operation. The special
JOG
mode is intended for operator
training or troubleshooting.
Содержание WF30T
Страница 2: ...WF30T Case Former ...
Страница 139: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 126 ...
Страница 140: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 127 ...
Страница 141: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 128 ...
Страница 142: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 129 ...
Страница 143: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 130 ...
Страница 144: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 131 ...
Страница 146: ...WF30T Case Former Appendix B MSDS Keystone Nevastane HT 2 133 ...
Страница 147: ...WF30T Case Former Appendix B MSDS Keystone Nevastane HT 2 134 ...
Страница 148: ...WF30T Case Former Appendix B MSDS Keystone Nevastane HT 2 135 ...
Страница 149: ...WF30T Case Former Appendix B MSDS Keystone Nevastane HT 2 136 ...
Страница 150: ...WF30T Case Former Appendix B MSDS Keystone Nevastane HT 2 137 ...