![Wexxar WF30T Скачать руководство пользователя страница 117](http://html.mh-extra.com/html/wexxar/wf30t/wf30t_operation-and-service-manual_966970117.webp)
WF30T
Case Former
Troubleshooting & Repairs
- 10-104 -
Table 53: Both forming head and jaw too slow
Problem
Possible Cause
Solution
Adjust the regulator’s set point.
Mast cylinder: 70 PSI.
Jaw cylinder: 70 PSI.
Regulator set point too
low
Other actuators: 90 PSI.
Insufficient air
compressor capacity
Increase the capacity of the air
compressor.
Supply air pressure set
too low
The supply air pressure regulator
should be set to 110 PSI (7.6 bar).
Depending on the length and the
inside diameter of the hose between
the machine and the regulator, the
pressure may have to be adjusted.
The maximum supply air pressure
should be 150 PSI.
Low Air
Pressure
Improper supply air-line
design
The minimum inside diameter of the
hose between the supply regulator
and the machine is ¾” (for flexible
hoses) or 1” (for steel tubes).
Auto drain of the filter
is not working; water
accumulated in the cup
is not discharged
Drain the water in the filter cup and
fix the auto drain valve or replace
the filter cup.
Water
Condensation
Too much water in the
supply air
Dry the air before it enters the
machine.
Overheating
Usually caused by high
ambient temperature
When ambient temperature is over
40° or below 0° centigrade.
Содержание WF30T
Страница 2: ...WF30T Case Former ...
Страница 139: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 126 ...
Страница 140: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 127 ...
Страница 141: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 128 ...
Страница 142: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 129 ...
Страница 143: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 130 ...
Страница 144: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 131 ...
Страница 146: ...WF30T Case Former Appendix B MSDS Keystone Nevastane HT 2 133 ...
Страница 147: ...WF30T Case Former Appendix B MSDS Keystone Nevastane HT 2 134 ...
Страница 148: ...WF30T Case Former Appendix B MSDS Keystone Nevastane HT 2 135 ...
Страница 149: ...WF30T Case Former Appendix B MSDS Keystone Nevastane HT 2 136 ...
Страница 150: ...WF30T Case Former Appendix B MSDS Keystone Nevastane HT 2 137 ...