B E L
2 9 0
F
U L L Y
A
U T O M A T I C
C
A S E
T
A P E
S
E A L E R
24
65-35-1 06/17/09
27) ‘PLC INPUTS’ Button
In the center-left side of the
‘Troubleshooting’
screen is the
‘PLC
INPUTS’
button. Touch this button to access the
‘PLC Inputs’
screen.
28) ‘PLC Inputs’ Screen
The
‘PLC Inputs’
screen displays 24 function indicators, for 24
machine functions. If one of the 24 machine components is not
functioning, the corresponding indicator will be flashing on and off.
Note that the function indicators are not buttons. They are not touch-
sensitive. Touch the
‘PREVIOUS’
button in the bottom right-hand
corner of the screen to return to the
‘Troubleshooting’
screen, or
touch the
‘MAIN CONTROL’
button in the bottom left-hand corner
of the screen to bring up the
‘Main Control’
screen.
‘PLC INPUTS’
Button
‘PLC INPUTS’
Status Indicator
‘PLC Inputs’ Screen
Содержание WF30T
Страница 2: ...WF30T Case Former ...
Страница 139: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 126 ...
Страница 140: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 127 ...
Страница 141: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 128 ...
Страница 142: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 129 ...
Страница 143: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 130 ...
Страница 144: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 131 ...
Страница 146: ...WF30T Case Former Appendix B MSDS Keystone Nevastane HT 2 133 ...
Страница 147: ...WF30T Case Former Appendix B MSDS Keystone Nevastane HT 2 134 ...
Страница 148: ...WF30T Case Former Appendix B MSDS Keystone Nevastane HT 2 135 ...
Страница 149: ...WF30T Case Former Appendix B MSDS Keystone Nevastane HT 2 136 ...
Страница 150: ...WF30T Case Former Appendix B MSDS Keystone Nevastane HT 2 137 ...