background image

Revision 1 - MAY 2023

115 Lowson Crescent  
Winnipeg, Manitoba, Canada   R3P 1A6
Phone: 866.300.1110        

wallaceperimetersecurity.com

ALPHA/DELTA

KINETIC 

OPERATOR

INSTALLATION AND 

MAINTENANCE MANUAL

1, 1S, 2, 2S Gate Operators

ALPHA

DELTA

Содержание ALPHA

Страница 1: ...MAY 2023 115 Lowson Crescent Winnipeg Manitoba Canada R3P 1A6 Phone 866 300 1110 wallaceperimetersecurity com ALPHA DELTA KINETIC OPERATOR INSTALLATION AND MAINTENANCE MANUAL 1 1S 2 2S Gate Operators...

Страница 2: ...66 300 1110 Copyright Notice Copyright2023allrightsreserved Nopartofthismanualmaybereproducedbyanymeans photocopier electronic or mechanical without the express written permission of Wallace Perimeter...

Страница 3: ...afety Instructions 20 Safety Standards Installer s Responsibility 21 Safety Standards Owner User Responsibility 23 Hazardous Materials and Proper Disposal 24 External Entrapment Protection Sensors 25...

Страница 4: ...n Requirements and Considerations 74 Connecting Peripherals to a Solar Operator 76 Understanding Gate Activity based on Solar Zones 77 Important Considerations for DC Power Connection 79 Installing th...

Страница 5: ...trapment Sensor Connections 127 Manual Push Button Station 128 User Relays Programming Procedure 129 Bi parting Gate Systems 134 Power Requirements 134 Primary and Secondary Wiring Connections 135 Pri...

Страница 6: ...Kinetic Schematics 166 General Maintenance 171 Smart Touch Analyze and Retrieve Tool S T A R T 171 Electrical Controls 173 Mechanical Maintenance 173 Software Maintenance 174 Drive Belt Tension and A...

Страница 7: ...Alpha Delta Kinetic Operator Installation and Maintenance Manual Revision 1 MAY 2023 7 KINETIC COMPONENTS Kinetic Components...

Страница 8: ...not share warranty registration information with parties unless the requested services transactions or legal requirements necessitate it Product Information Model name number ______________________ Se...

Страница 9: ...ble 12VDC and 24VDC are available to power accessory controls An optional base extension is required to provide space for the optional 50Ah batteries which support solar applications or usage during e...

Страница 10: ...e company website at www wallaceperimetersecurity com or call 866 300 1110 Alpha Delta Kinetic Operator Gate System The Kinetic automatic gate operator is designed to open and close two types of Walla...

Страница 11: ...n Listed to UL 325 class 1 2 3 4 Alpha Delta Applications Airports Seaports Commercial Facilities Water Treatment Facilities Public Transportation Alpha Delta models are cantilever gate systems trackl...

Страница 12: ...And install the supplied WARNING sign on both sides of the gate Check for compliance with local codes site conditions and NEC standards When turning the power OFF and ON to demonstrate learn limits af...

Страница 13: ...umper is 1 4 to 1 2 2 Run on Plate Make sure that the run on plate is mounted in the proper location on the catch portal It should not sit too low so that the gate leaf is suspended in the air nor sho...

Страница 14: ...te Portals Ensure gate portals are in line and level 8 Operator When mounting the operator cabinet the right height is very critical If mounted too high the gate leaf will put extreme pressure on the...

Страница 15: ...ing For UL 325 compliancy ensure signage is installed near the gate visible from each side of the gate and not ON the gate since they should be seen whether the gate is fully open or fully closed Each...

Страница 16: ...out false detections Ensure loop phasing is correct 17 Loop Inspection Ensure all of the ground loop path is covered with sealant Exposed areas should be resealed 18 Accessory Device Programming Progr...

Страница 17: ...wer Loss setting is set to AP0 AP1 AP2 or AP3 26 SmartDC Controller Batteries Check batteries for physical wear and corrosion on leads Clean if needed Test battery input and output voltage via the Sma...

Страница 18: ...ion of thermal cover if required 30 Motor Brushes Check motor brushes for wear Brushes should be replaced every 2 years 31 Thermal Cover Thermostat If supplied as part of the installation ensure the t...

Страница 19: ...ould occur if the hazardous situation is not avoided Indicates mild or moderate injury could occur if the hazardous situation is not avoided Indicates damage to equipment is probable if the hazardous...

Страница 20: ...eath Start the gate operator only when the gate s travel path is clear Hazards associated with automatic gates can be reduced with proper site design installation and use Installers maintenance crew a...

Страница 21: ...revent the gate from falling in the event of a roller failure Before attaching the operator to the gate slide the gate in both directions Make sure it is level and moves freely A gate that slides easi...

Страница 22: ...so they are clearly visible from both sides of the gate Installing the signs is a requirement for UL 325 compliance Connect radio and other remote access non resetting controls to the RADIO OPTIONS te...

Страница 23: ...o turn the power on and off Learn how to manually release the gate Before attempting a manual release make sure the gate is not moving WARNINGsignssuppliedwiththegateoperator must remain installed and...

Страница 24: ...tery sizes types or brands The charging circuit on Wallace Perimeter Security DC operators is designed for AGM type batteries not lead acid type batteries Wallace Perimeter Security strongly recommend...

Страница 25: ...trian entrapment in BOTH directions of the gate travel and where an entrapment hazard exists PHOTOELECTRIC EYES One or more photoelectric eyes shall be located where the risk of entrapment or obstruct...

Страница 26: ...er your specific installation to determine where the greatest entrapment risks exist Locate edge sensors and or photoelectric sensors accordingly Be certain that a sufficient number of sensors are use...

Страница 27: ...gs or a parking area associated with one to four single family dwellings Class II Class II Intended for use in a commercial location or building such as multi family housing units five or more single...

Страница 28: ...installed to detect possible entrapment To comply with UL 325 refer to the chart and take the following steps 1 Select the Usage Class according to the gate s locale and purpose 2 The required UL 325...

Страница 29: ...UL 325 7th Edition Select sensors from this list for UL compliant gate automation solutions Contact the sensor manufacturer for specific recommendations for use Recommended External Entrapment Protect...

Страница 30: ...s are now defined for each gate type Clauses 4 23 4 24 4 29 4 34 of the Standard Slide Gates To enable fully automatic operation all SLIDE gate operators will require a minimum of TWO monitored extern...

Страница 31: ...ator s DC power is turned off You DO NOT need to turn AC power off to manually push the gate See NOTE When you turn the DC power off the following occurs The motor disengages which makes it easier to...

Страница 32: ...he aluminum beams by hand Use a cart if available 3 Contents are fragile Take care when moving 4 The pallets are built with openings at the bottom to be securely lifted by a forklift 5 IMPORTANT TO NO...

Страница 33: ...gonal braces Both gate models feature a rack and pinion drive concealed nylon rollers and anti climb top rail Kinetic Gate installation should only be carried out by personnel qualified by Wallace Per...

Страница 34: ...com Phone 866 300 1110 ALPHA DELTA GATE INSTALLATION Be sure to attach the WARNING signs on both sides of the gate but NOT ON the gate For your records take a photograph of the completed installation...

Страница 35: ...Alpha Delta Kinetic Operator Installation and Maintenance Manual Revision 1 MAY 2023 35 ALPHA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS ALPHA Gate Model Step by Step Installation Diagrams ALPHA...

Страница 36: ...36 wallaceperimetersecurity com Phone 866 300 1110 ALPHA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS ALPHA...

Страница 37: ...Alpha Delta Kinetic Operator Installation and Maintenance Manual Revision 1 MAY 2023 37 ALPHA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS ALPHA...

Страница 38: ...38 wallaceperimetersecurity com Phone 866 300 1110 ALPHA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS ALPHA...

Страница 39: ...Alpha Delta Kinetic Operator Installation and Maintenance Manual Revision 1 MAY 2023 39 ALPHA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS ALPHA...

Страница 40: ...40 wallaceperimetersecurity com Phone 866 300 1110 ALPHA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS ALPHA...

Страница 41: ...Alpha Delta Kinetic Operator Installation and Maintenance Manual Revision 1 MAY 2023 41 ALPHA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS ALPHA...

Страница 42: ...42 wallaceperimetersecurity com Phone 866 300 1110 ALPHA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS ALPHA...

Страница 43: ...Alpha Delta Kinetic Operator Installation and Maintenance Manual Revision 1 MAY 2023 43 ALPHA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS ALPHA...

Страница 44: ...44 wallaceperimetersecurity com Phone 866 300 1110 ALPHA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS ALPHA...

Страница 45: ...Alpha Delta Kinetic Operator Installation and Maintenance Manual Revision 1 MAY 2023 45 ALPHA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS ALPHA...

Страница 46: ...46 wallaceperimetersecurity com Phone 866 300 1110 DELTA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS DELTA Gate Model Step by Step Installation Diagrams...

Страница 47: ...Alpha Delta Kinetic Operator Installation and Maintenance Manual Revision 1 MAY 2023 47 DELTA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS...

Страница 48: ...48 wallaceperimetersecurity com Phone 866 300 1110 DELTA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS...

Страница 49: ...Alpha Delta Kinetic Operator Installation and Maintenance Manual Revision 1 MAY 2023 49 DELTA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS...

Страница 50: ...50 wallaceperimetersecurity com Phone 866 300 1110 DELTA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS...

Страница 51: ...Alpha Delta Kinetic Operator Installation and Maintenance Manual Revision 1 MAY 2023 51 DELTA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS...

Страница 52: ...52 wallaceperimetersecurity com Phone 866 300 1110 DELTA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS...

Страница 53: ...Alpha Delta Kinetic Operator Installation and Maintenance Manual Revision 1 MAY 2023 53 DELTA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS...

Страница 54: ...54 wallaceperimetersecurity com Phone 866 300 1110 DELTA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS...

Страница 55: ...Alpha Delta Kinetic Operator Installation and Maintenance Manual Revision 1 MAY 2023 55 DELTA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS...

Страница 56: ...56 wallaceperimetersecurity com Phone 866 300 1110 DELTA GATE MODEL STEP BY STEP INSTALLATION DIAGRAMS...

Страница 57: ...netic 1 Kinetic DC 10FW Kinetic 2 Duty cycle continuous Duty cycle continuous Power single phase Switch selectable Power single phase Switch selectable 115 volts 3 amps 50 60 Hertz 115 volts 3 amps 50...

Страница 58: ...mm button head screws on the side of the operator that will be mounted to the gate post See Figure 2 Discard the screws 2 Place the Spacers between the operator and gate post Align the spacers with th...

Страница 59: ...usting the Spur Gear Alignment 1 To adjust spur gear alignment with the tooth rack loosen but DO NOT REMOVE the two 2 20 x 2 0 retaining bolts and lock nuts on spur gear See Figures 5 and 6 2 Insert t...

Страница 60: ...the Tooth Rack Hook tooth racks together and slide them into rail throughout the entire length of gate See Figure 8 Tooth racks can be 80 2cm to 1 18 3cm shorter than gate length tooth rack must not...

Страница 61: ...fore the Kinetic operator will function Once the configuration is complete the information is retained even when a power loss occurs Table 1 Menu Mode Navigational Buttons To edit the menu To navigate...

Страница 62: ...ight GATE WEIGHT SELECTIONS 0 Gate weight not set Kinetic DC 15W Kinetic 1 1 Gate weight 0 to 400lbs 0 to 181kg 2 Gate weight 401 to 800lbs 181 to 363kg 3 Gate weight 801 to 1100lbs 363 to 499kg 4 Gat...

Страница 63: ...n memory 2 Hold the CLOSE button until the gate slides to full close Release the CLOSE button press STOP twice to store the full close location in memory Note Pressing the OPEN button will reverse dir...

Страница 64: ...ied service technician with proper training should perform this installation Follow all shop safety rules when performing this installation Preparation 1 Make sure AC and DC power is turned off 2 Unlo...

Страница 65: ...Alpha Delta Kinetic Operator Installation and Maintenance Manual Revision 1 MAY 2023 65 TARGET SENSOR RACK DRIVE INSTALLATION INSTRUCTIONS Target Magnet Sensor Installation...

Страница 66: ...rd the operator 4 Drill a 3 8 9 5mm diameter hole in gate beam and tooth rack 7 8 22mm deep as shown in Figure 14 5 Apply a small amount silicone into 3 8 9 5mm hole in gate beam tooth rack Fully pres...

Страница 67: ...AC power switches and watch the display go blank Then turn both switches on The operator beeps indicating Limit Relearn Mode The gate then travels about 6 inches 15cm in the open direction and stops...

Страница 68: ...ate earth ground rod you risk voiding the Limited Warranty For earth grounding requirements refer to the National Fire Protection Association NFPA 780 Standard for the Installation of Lightning Protec...

Страница 69: ...ING THE EARTH GROUND Properly grounding the gate operator is critical to gate operator performance and the life of its electrical components Use sufficient wire size during installation Refer to Wirin...

Страница 70: ...oth the DC and AC power switches on the side of the Kinetic control box are in the off position See Figure 16 Wiring of gate operators must conform to the NEC standards and comply with all local codes...

Страница 71: ...rcuit with an accessory power load up to 2A Additional loads require that the wire size be increased or the distance of the run be decreased To connect to 115VAC power take the following steps 1 Make...

Страница 72: ...iscussed in Wiring 115VAC Power Maximum gate system current draw is 1 5 amps on a dedicated 230VAC circuit 20A dedicated circuit is recommended Make sure the proper wire size is used The following tab...

Страница 73: ...screwing the two Phillips head screws that secure it See Figure 16 Wiring AC Power on page 70 3 Toggle the voltage selector switch from 115V to 230V See Figure 17 Replace the cover and secure it 4 Acc...

Страница 74: ...iring Connections on page 75 5 Wire nut or crimp bond the equipment ground wire to the green ground wire in the junction box 6 Slide the plastic cover off the control box and attach the red spade conn...

Страница 75: ...Alpha Delta Kinetic Operator Installation and Maintenance Manual Revision 1 MAY 2023 75 USING A SOLAR POWERED OPERATOR Figure 19 Kinetic DCS Control Box Figure 18 Solar Panels and Wiring Connections...

Страница 76: ...o a Solar Operator Photoeyes connected to these terminals receive power when the motor engages which means the draw on the battery is minimal Figure 20 Connecting Peripherals to a Solar Operator Photo...

Страница 77: ...or more information on photo eyes refer to the section titled Installing Photoelectric Sensors for External Entrapment Protection Only on page 145 To review information about vehicle detectors refer t...

Страница 78: ...gate with the following peripherals attached One low current multi code radio receiver Two HY5B vehicle detectors The number of amps that the peripherals draw coupled with the gate travel occurring t...

Страница 79: ...f use especially in hot climates Properly discard used batteries Refer to Hazardous Materials and Proper Disposal on page 24 Batteries are rated to perform to capacity at certain temperatures Variatio...

Страница 80: ...black terminal on the other 50Ah battery 6 Run the red and black wires disconnected from the 8Ah batteries through the hole in the support bracket 7 Using the wires supplied in the 50Ah battery kit a...

Страница 81: ...EXTENDED BATTERY BACKUP KIT 2 Access the User Menu by pressing MENU twice 3 Access the Installer Menu by simultaneously pressing OPEN and RESET Release the buttons 1 Start at a gate status display 4 U...

Страница 82: ...ed Adjust IES Sensitivity Reinstate Factory Defaults Enable Fire Department Access This section describes what you will see on the display and explains the functionality of the buttons User and Instal...

Страница 83: ...5 NO TARGET or LEARN OPEN appears on the display For more information refer to Installing the Target Magnet on page 66 2 When the target magnet is detected the software version briefly appears on the...

Страница 84: ...wer When AC power is lost the rate of flashing slows down Another indicator light above the display is multi colored and corresponds to the action that the operator is performing Green the operator is...

Страница 85: ...rator mode Three different modes exist Run Mode gate is operational awaiting commands Refer to Using the SmartDC Controller Buttons in RUN Mode herein Menu Mode motor disengages and operator commands...

Страница 86: ...ces a card reader push button remote or recognition of a vehicle passing over a free exit loop detector In all cases the operator runs the motor when it receives a gate operation command Understanding...

Страница 87: ...iting commands Menu Mode motor disengages and operator commands are ignored Menu navigation and menu selection can be accomplished using the SmartDC Controller buttons or through a S T A R T software...

Страница 88: ...Description This display appears only when you press RESET or cycle the power It displays the software version which is useful as a maintenance tool Indicates in a dual gate setting whether the opera...

Страница 89: ...Press the NEXT button to cycle through the available menu items 3 Review Table 5 SmartDC Controller User Menu Functions on page 94 which supplies the factory defaults for the User Menu items and refe...

Страница 90: ...ected to the unit such as a push button station To adjust the time 1 to 99 seconds it takes before the operator initiates gate closure take the following steps 1 At a gate status display press the MEN...

Страница 91: ...rs 3 Press SELECT CL blinks 4 Press NEXT or PREV to change the number to 1 5 Press SELECT to accept the display 6 The date and time display appears Use the SELECT and NEXT buttons in the same manner a...

Страница 92: ...sh button CLOSE command will close the gate If the battery continues to diminish and the system detects 18V or less the system initiates an automatic open cycle Any new open or close command is ignore...

Страница 93: ...R display appears Press the NEXT button until the LCD CONTRAST display appears 2 Use the SELECT and NEXT buttons to navigate and change the number on the display 3 To exit the User Menu press the MENU...

Страница 94: ...setting of 1 also deactivates the automatic close timer and causes its menu to disappear You must set HC to 1 to comply with UL 325 Type D protection Refer to Table Notes on page 97 COM CLOSE 3 HO 0...

Страница 95: ...y or death 7 PE 0 OFF PHOTO EYE ALIGN 0 off 1 on When set to 1 the operator serves as an aide in photo eye transmitter receiver alignment The buzzer chirps once when the emitter and the receiver are n...

Страница 96: ...3 second warn before operate buzzer alarm and then initiates a closure if the gate is forced open and the closed limit switch disengages The motor restarts to secure the gate If the gate does not full...

Страница 97: ...owing conditions apply to the indicated reference numbered menu selections Table Note 1 For gate operators using Type D entrapment protection an automatic closing device such as a timer loop sensor or...

Страница 98: ...ust be configured before the operator will function Refer to Programming the Initial Setup Menu on page 61 In the pages that follow a detailed view of the more commonly used menus is provided To acces...

Страница 99: ...open limit 4 Hold the OPEN button until the gate reaches the desired open limit Release the OPEN button Note that if you go too far you can press CLOSE to reverse direction 5 Press STOP twice to pres...

Страница 100: ...c DC 15W Kinetic 1 0 0 75 ft s 1 1 00 ft s Usage Class 3 4 only 2 1 25 ft s Kinetic DC 10FW Kinetic 2 4 1 75 ft s The DC 10FW is designed for Usage Class 3 4 only 5 2 00 ft s 6 2 25 ft s NOTE Certain...

Страница 101: ...e IES to trip could cause severe injury or death to people caught in the moving gate For IES settings 0 through 6 the motor current is continually being measured and the IES threshold automatically se...

Страница 102: ...etting until repairs are made Gate maintenance Gate rollers will deteriorate and begin to fail over time Gravel or dirt roads will incur more debris in the gate rail or inverted V track than a paved s...

Страница 103: ...9 setting The high motor current required for the IES to trip could cause severe injury or death to people caught in the moving gate 1 Start at a gate status display 2 To access the User Menu press ME...

Страница 104: ...FD 1 the factory settings are reinstated immediately and the menu display returns to the initial Setup Menu The gate operator will not run until the three menu parameters are entered Usage Class Gate...

Страница 105: ...Installer Menu At a gate status display press the MENU button twice This accesses the User Menu and the CLOSE TIMER display appears 3 Simultaneously press the OPEN and RESET buttons to enter the Insta...

Страница 106: ...t applicable N A 2 LL 0 LEARN LIMITS 0 Normal operation 1 Reset limits A setting of 1 places the operator into its learn limits mode which allows you to reset the gate s open and close positions Refer...

Страница 107: ...ation and deceleration rates N A 7 OS 1 OPEN SPEED DC 15 DC 10F 0 0 75ft s 4 1 75ft s 1 1 0ft s 5 2 0ft s 2 1 25ft s 6 2 25ft s Designate how quickly the gate opens The options available differ depend...

Страница 108: ...COM Gate 1 to Dual Gate COM Gate 2 Pair wires A A COM COM and B B 11 SG 0 OFF SEQUENCED GATE 0 solo operator 1 Loop View 1 2 Loop View 2 3 Loop View 3 4 Loop View 4 Establishes communication after wir...

Страница 109: ...ivity make sure that the gate rolls smoothly without obstruction Fix any issues with gate hardware See Note 16 SS 0 OFF IES STOP ONLY 0 stop reverse for 2s 1 stop only In a Usage Class 4 environment t...

Страница 110: ...Sensor Input 22 EO 0 STOP ONLY EYE OPEN LOGIC 0 Open eye stops only 1 2s reverse to close The default setting is non reversal if the open photo eye is triggered A setting of 1 causes the gate to reve...

Страница 111: ...input setting for external entrapment protection sensor monitoring All three sensor types must be configured to a non zero number before the gate operator will move the gate Edge Both is only availabl...

Страница 112: ...ly close when all loop detectors are not triggered Refer to Vehicle Detector Configuration and Quick Close Mode Selection on page 126 HY5A HY5B HY5B 2 0 34 RL 1 0 DISABLED RELAY 1 LOGIC 0 Default 1 to...

Страница 113: ...38 LT 2 45 SECS LOITERING ALERT 0 0 seconds 1 15 seconds 2 45 seconds 3 75 seconds 4 105 seconds 5 135 seconds This function monitors activation of the Outside Obstruction Loop when there is no activ...

Страница 114: ...MODE OUT OBS LOOP SET 0 Run mode 1 Show frequency 2 Show call level 0 7 3 Set Frequency Controls the HY5A HY5B HY5B 2 0 Outside Obstruction Loop detector If an HY5B is used additional settings of 4 8...

Страница 115: ...SmartDC Controller board its inputs for peripheral connections and its monitoring capabilities This section explains how to 1 Make connections on the SmartDC Controller 2 Perform a Preliminary Test of...

Страница 116: ...nt For operators that use only DC power you can push a button to show the active inputs This button is at the bottom left corner near the EMERG OPEN input On a new operator no active inputs should app...

Страница 117: ...d when connected to common except Emergency Open All inputs except Emergency Open 9 Stop push button Normally Closed N C input Jumper to Common if not being used Line of sight external stop button or...

Страница 118: ...he Free Exit detector will trigger the gate to open fully Input can be converted in Installer Menu to alternately disable Close Timer 18 Inside Obstruction Vehicle Detector N O input Inside reversing...

Страница 119: ...ached This terminal is used to per form monitored entrapment check 23 24V DC Convenient 24VDC power for photo eyes or the Emergency Open input Convenient 24VDC power for photo eyes or Emergency Open i...

Страница 120: ...lity during a power failure and for solar operations Cross talk between multiple loops is impossible Best operating frequency for each loop is automatically selected Loop frequency and call strength c...

Страница 121: ...ng to the following procedure 1 Turn off both AC and DC power switches 2 Insert the locking end of the two white plastic standoffs into the mounting holes on the detector 3 Plug the detector into the...

Страница 122: ...ustment available on the detector itself Generally sensitivity does not need to be increased unless the loop is large or there are multiple loops connected to one detector If required adjust the sensi...

Страница 123: ...ops have cleared 2 Quick close Close Timer can count to zero even while loops are active so the gate will close as soon as the loops are clear 3 Forced time out Close Timer is forced to zero when both...

Страница 124: ...stead If standard 11 pin box type vehicle detectors are to be used perform the following procedure 1 If there is sufficient space install the sockets in the control box if not then install them in a s...

Страница 125: ...Always keep the detector loop wires well twisted at all places beyond the area of the loop The lead in portion sealed in a saw cut does not need to be twisted so long as the wires are encapsulated in...

Страница 126: ...ted to zero the gate will close when all detector inputs are clear Center Loop has no gate control function in a slide gate However the input may be used as an arming loop when used in conjunction wit...

Страница 127: ...ices such as gate edge sensors and photoelectric beams must be installed to protect against entrapment These external entrapment protection devices are required so the gate installation is in complian...

Страница 128: ...nd closes the gate It is most often used by a guard in a 24 hour guard station An example of the push button station connections on the Kinetic DC operators shown in Figure 33 Make sure the manual pus...

Страница 129: ...Enter the appropriate function using the associated number 1 through 45 listed in the table Table 9 User Programmable User Relays Function Options No Name Description 1 Close limit output Creates an...

Страница 130: ...of time Adjustable from a 0 second to 135 second delay in 30 second increments Note TL OPEN TIME ALERT adjustments can be made in the Installer Menu 9 Safety Mode Alert output Activated when system is...

Страница 131: ...h loss of AC power 18 DC Power Failure output Activated when the battery power is very low but the output ceases when the battery is dead The relay is triggered when the battery is less than 20 volts...

Страница 132: ...when the gate is not on open limit and AC power is present Deactivated when AC power fails or the gate is on open limit 29 Arm Entry Ticket Dispenser Not functional in the Kinetic operator 30 Arm Exit...

Страница 133: ...lly used for cycle testing 42 Break Away Switch output Activates when the arm break away switch is tripped 43 Warn Before Combination of relays 5 and 16 44 Partial Open Limit Pulse Pulses for 250ms wh...

Страница 134: ...are correct as solo operators before interconnecting them External control inputs vehicle detectors and entrapment protection sensors may be connected to either gate operator without regard to prefere...

Страница 135: ...er Be sure to connect the wires in pairs to the same terminal ports A A B B and COM to COM on both units See Table 11 2 Attach a ring terminal to the shield wire and connect it to the SmartDC Controll...

Страница 136: ...r Menu press the MENU button A gate status appears in the display indicating you have returned to Run Mode NOTE For proper operation you must set the other gate operator as SECONDARY 6 Move to the oth...

Страница 137: ...power switch is turned off in one unit both operators cease to function and an ERROR 4 Primary Secondary Communication Error appears in the display 4 Use NEXT to navigate to the menu display Change th...

Страница 138: ...tions are needed because the common wire and one radio output wire are connected together Figure 36 shows additional wires from a two channel receiver 3 Make sure to observe polarity and crimp togethe...

Страница 139: ...he 24VDC or 12VDC power supply If the peripherals attached to the terminals need more than 1 amp a separate power supply is required Refer to Overview of the SmartDC Controller and Figure 29 SmartDC C...

Страница 140: ...ower supply to one lead of the lock s coil See Figure 38 2 Connect the other lead of the lock s coil to NO on USER 1 RELAY NOTE Connect to NC on USER 1 RELAY if installing a maglock 3 Connect the COM...

Страница 141: ...the SmartDC Controller buttons to program the user relays by selecting the relay you wish to use and entering the appropriate function using the associated number listed in Table 9 User Programmable U...

Страница 142: ...different frequencies An advantage of using HySecurity model HY5B detectors is that problematic cross talk is not possible 3 For greater sensitivity and less chance of false calls caused by the motio...

Страница 143: ...ic HySecurity recommends that vehicle detectors be used for free open and obstruction sensing logic only Because of their slower speeds closing logic is a poor choice for security gate systems Since t...

Страница 144: ...144 wallaceperimetersecurity com Phone 866 300 1110 INSTALLING VEHICLE DETECTORS AND LOOPS Figure 41 Installing Vehicle Detectors and Loop Layout...

Страница 145: ...ons to SmartDC Controller as shown in Figure 43 on the next page Operation Notes A photo eye trip does not reverse gate The SmartDC Controller software is factory set to stop upon photo eye trip Softw...

Страница 146: ...rapment Protection Only If the photo eye has an internal switch for setting Light Operate vs Dark Operate select Light Operate If the photo eye has a relay output and has both NO and NC terminals some...

Страница 147: ...tial mounting and alignment of the 3 inch 7 62cm reflector the chance of problems is greatly reduced Use only through beam photo eyes for a distance greater than 24 feet 7 32m because the function of...

Страница 148: ...ge s mounting channel and through the surface that each gate edge is to be mounted Securely fasten every edge sensor Protect the area wherever a potential pinch point exists for any type of entrapment...

Страница 149: ...enna type in the channel of the chassis on either side of the operator Mount an external antenna onto the top of a fixed post of the fence near the operator Connect the antenna into the socket on the...

Страница 150: ...per 9 Earth ground 10 Terminal block Normally Closed Monitoring Connect Power Wires Last For channels assigned to Relay 1 connect the sensor common to terminal 6 and the operator input sensor 1 2 or 3...

Страница 151: ...ontroller system includes many self diagnostics Specific messages appear on the LCD and the Audio Alert buzzer sounds distinctive chirps Any alerts faults or errors are also logged into memory and dat...

Страница 152: ...Gate binding wind a faulty edge sensor or worn motor brushes can cause a false alert 1 Remove the obstruction 2 Adjust the IES sensitivity 3 Correct the gate hardware 4 Correct faulty edge sensor 5 C...

Страница 153: ...teries are 80 depleted Normal function until 21V 1 No AC Power See item 3 above 2 Wiring Connector problem check all connections Clean or repair as required 3 Check battery condition 4 SmartDC Control...

Страница 154: ...erator for too long and the batteries are drained Wiring problem Batteries no longer hold a charge Bad SmartDC Controller Bad transformer 1 No AC power See item 3 above 2 Wiring Connector problem chec...

Страница 155: ...0 F 98 89 C The alert will temporarily disable the operator but will automatically reset itself when it cools down Check gate hardware weight length of gate Alert automatically clears when the tempera...

Страница 156: ...and re install the HY5B and press RESET Replace the HY5B if necessary 19 ALERT 11 DETECTOR FAULT The SmartDC Controller has detected a problem within a HY5B vehicle detector Caused by a fault within...

Страница 157: ...net fell off or target sensor wires are damaged Target position has not been learned after setting limits 1 Make sure target is properly fastened to the chain 2 Check the target sensor to make sure it...

Страница 158: ...ual gate or sequenced gate operators 1 Check cable connections and wiring Make sure both operators are working properly and have the same current and up to date software versions The alert auto clears...

Страница 159: ...p Was Error 9 in pre h5 57 software versions Replace or reconnect batteries to the controller 35 FAULT 2 PHOTO EYE The photo eye is missing or not working This fault can only occur if the special supe...

Страница 160: ...ss RESET to clear fault 40 ERROR 1 DIRECTION ERROR The SmartDC Controller has detected that operator ran in the wrong direction Motor wiring 1 Check motor wiring and correct as needed 2 Press RESET to...

Страница 161: ...rly through the Installer Menu One operator must be set as Primary and the other operator must be set as Secondary using the Installer Menu 3 Install ground rod per NEC NFPA standard 4 Install separat...

Страница 162: ...board 47 ERROR 9 BATTERY DISCONNECT The SmartDC Controller detected there is no battery connected The batteries are disconnected or a wiring fault exists Kinetic operators ship with a wire disconnecte...

Страница 163: ...the loop and lead in wires are shorting out Check the wires for problems Replace them if necessary ALERT 9 LOOP OPEN HY5B vehicle detector Disconnected loop alert The alert indicates the loop wires ar...

Страница 164: ...re required to retrieve and read this data Loop Health The HY5B monitors loop health which is comprised of loop noise loop step changes and loop reference changes Loop health readings accumulate throu...

Страница 165: ...is on loop when power returns Frequency Knowing the exact frequency of a loop can be useful as a diagnostic tool and verifying the stability of the loop frequency is valuable information To view the a...

Страница 166: ...ll Level Display Installer Menu LCD Description Setting Options Bold Factory Settings ELD 0 EXIT LOOP SET 0 Run Mode 1 Show frequency 2 Show call level 0 7 3 Set Frequency 4 Show Sensitivity 5 Set Sen...

Страница 167: ...Figure 47 Schematic for Kinetic DC 15 Kinetic 1 and Kinetic DC 10F Kinetic 2 Operator s...

Страница 168: ......

Страница 169: ...Figure 48 Schematic for Kinetic DCS 15 Kinetic 1S and Kinetic DCS 10F Kinetic 2S Solar Operator s...

Страница 170: ......

Страница 171: ...ble management tool for all styles of Kinetic operators Either the USB port or the RS 232 serial port found on the SmartDC Controller see Figure 49 allows you to download system diagnostics and upload...

Страница 172: ...T software onto your laptop Take the following steps In Windows 7 Go to Start Menu Control Panel User Accounts User Account Change User Account Control Settings slide the slide bar to the lowest valu...

Страница 173: ...g the internal mechanisms of the operator turn OFF all power switches The Kinetic mechanical maintenance is not in depth or difficult but should be performed on a routine basis The operator chassis is...

Страница 174: ...to check the Nice HySecurity website for the latest version of software before heading out for field maintenance Use S T A R T software to download the latest software version to a PC laptop and uplo...

Страница 175: ...elt If it is properly tensioned it should only move about 1 16 inch to 1 8 inch 1 6 to 3 2mm See Figure 50 Drive Belt Tension and Alignment on page 174 5 To replace or re tension the drive belt loosen...

Страница 176: ...er display Gate operation is affected by AC power loss depending on customer preferences and the configuration set by the installer in the AP AC LOSS User Menu For detailed information about the AP AC...

Страница 177: ...eries and disconnect battery wires cut the two black wire ties and slide the 8Ah batteries through the access window See Figure 51 Another option is to remove the four screws that hold the control box...

Страница 178: ...removing the batteries through the access hole an optional method for battery replacement is to remove the control box Four Phillips head screws secure the control box to the chassis Remove the screw...

Страница 179: ...d to the correction of the defect by repair or replacement The foregoing warranty shall not apply to defects resulting from improper or inadequate maintenance by Buyer Buyer supplied software or inter...

Страница 180: ......

Страница 181: ...sun for 3 hours Horsepower hp hp hp Accessory Power 1 amp each at 12VDC and 24VDC 1 amp each at 12VDC and 24VDC 1 amp each at 12VDC and 24VDC Communication USB RS232 RS485 USB RS232 RS485 USB RS232 RS...

Страница 182: ...115 Lowson Crescent Winnipeg Manitoba Canada R3P 1A6 Phone 866 300 1110 wallaceperimetersecurity com...

Отзывы: