Compressor power supply
A
Terminals at the control module
Recommended core cross-section:
1.5 mm
2
Note
The upstream fuses must have Z
characteristics.
Instantaneous heating water heater power supply
A
Terminals in the control panel
Max. fuse rating 16 A
Recommended core cross-section:
2.5 mm
2
The three heating elements are
switched by inserting jumpers across
X60.8, X60.9 and X60.10 in star for-
mation and must be connected to N.
230 V~ power supply, various tariffs
&
Three separate power cables
&
Selective power-OFF for compressor and instantaneous heating water heater
possible
The cross-section of the power supply lines must be appropriate for the con-
nected load of the relevant unit.
Power supply
(cont.)
93
Installation sequence
55
92
968
GB
Installation
Содержание VITOCAL 200-G
Страница 8: ...Certificates Declaration of conformity 201 Keyword index 202 Index cont 8 Index 5592 968 GB ...
Страница 65: ...Installing the heat pump module and making the cont 65 Installation sequence 5592 968 GB Installation ...
Страница 122: ...Main menu Information Menu structure overview information 122 Control settings 5592 968 GB ...
Страница 187: ...Parts lists cont 187 Parts lists 5592 968 GB Service ...
Страница 188: ...Parts lists cont 188 Parts lists 5592 968 GB ...
Страница 189: ...Parts lists cont 189 Parts lists 5592 968 GB Service ...
Страница 206: ...206 5592 968 GB ...
Страница 207: ...207 5592 968 GB ...