One heating circuit without mixer, with DHW heating and natural cooling
Note
To achieve this system version, select
system design 2
at the control unit.
Hydraulic diagram
A
DHW cylinder interface (see from
page 51)
B
Primary side interface (see from
page 15)
C
Min. 500 mm (for hydraulic
separation)
1
Heat pump
6
Diaphragm expansion vessel
7
Underfloor heating system tem-
perature limiter
8
Plate-type heat exchanger
qP
Underfloor heating circuit
qR
Natural cooling extension kit
qU
KM BUS distributor
qI
Vitotrol 200 remote control
qO
Room temperature sensor