A
Inserting the external electrical
cables
1.
Route external electrical cables to
the rear left upper edge of the unit
and cut to length, leaving approx.
1800 mm of cable
inside the unit
.
2.
!
Please note
Damage to the insulation of
the electrical cables can
result in short circuits.
Route cables so that they
cannot touch very hot,
vibrating or sharp-edged
components. Secure cables
with cable ties.
Route cables to control panel
through one of the available cable
entries
A
. In doing this, separate
the LV cables from those carrying
mains voltage, and tie up both
types of cable separately.
Inserting the electrical cables and power supply connections