Synergy Controller Technical Manual, Revision H
Page 201
Compressor
This output turns on a compressor.
Output is On/Off
Control Parameters
Default Value:
Range:
xL1 Channel x Main Cooling Turn On
Cooling output required to turn on channel x cooling
xL2 Channel x Main Cooling Turn Off
Heat output required to turn off channel x main cooling
L9 Ramp Up Cooling
Temperature at which to turn off the cooling compressor
while heating
L15 Compressor
Delay in minutes required before turning off the
compressor
Notes:
Setpoint direction is Positive only when ramping a setpoint in a profile
* Denotes which signal has priority if both are true
Содержание Synergy Compact
Страница 14: ...Synergy Controller Technical Manual Revision H Page 14 2 0 SPECIFICATIONS 2 1 Data Sheet...
Страница 71: ...Synergy Controller Technical Manual Revision H Page 71...
Страница 106: ...Synergy Controller Technical Manual Revision H Page 106...
Страница 123: ...Synergy Controller Technical Manual Revision H Page 123...
Страница 141: ...Synergy Controller Technical Manual Revision H Page 141 TE1151 6 Triac Output Board Schematic...
Страница 142: ...Synergy Controller Technical Manual Revision H Page 142 TE1708 6 Relay Board Schematic...
Страница 188: ...Synergy Controller Technical Manual Revision H Page 188...
Страница 274: ...Synergy Controller Technical Manual Revision H Page 274 Synergy Controller Step Syntax...
Страница 294: ...Synergy Controller Technical Manual Revision H Page 294...
Страница 312: ...Synergy Controller Technical Manual Revision H Page 312...
Страница 345: ...Synergy Controller Technical Manual Revision H Page 345...
Страница 346: ...Synergy Controller Technical Manual Revision H Page 346...