Synergy Controller Technical Manual, Revision H
Page 288
Email and Fax Alert System
In addition to monitoring and control, the
Synergy Manager employs a highly
configurable Alert Notification System. Once
enabled, any specified recipients are notified
of all errors and alarms via email or fax.
The alarms are separated into eight categories. The user can assign a different priority to each
category. For example, you might want all chamber alarms to have a high priority and be emailed
immediately upon the sounding of the alarm. However, for communications errors that may be caused by
transient noise on the line, you may want to have set as a low priority. All low priority errors would then be
compiled in a general report that is mailed out once a week. The exact definition of each priority level is also
user definable: high, medium or low priority items can be specified as sent immediately, once an hour, once
a day or once a week, at any specified time.
Hardware Requirements
The minimum hardware requirements for Synergy Manager are as follows:
♦
A Pentium 233 MHz or better
♦
128 MB ram plus 32 MB for each simultaneous chamber session
♦
80 MB hard disk space
♦
One serial port
♦
One National Instruments GPIB IEEE interface (Optional)
♦
One 10/100 Ethernet card using TCP/IP (Optional)
♦
One USB external hardware Dongle (Parallel port type needed for NT 4.0) (see ‘External Hardware
Dongle’).
♦
Printer (Optional)
♦
Fax Modem (Optional)
♦
Microsoft Windows™ PC Operating systems:
o
Microsoft Windows™ 95
o
Microsoft Windows™ 98
o
Microsoft Windows™ 98 Special Edition
o
Microsoft Windows™ NT 4.0 Service Pack 6a
o
Microsoft Windows™ 2000 Service Pack 2
o
Microsoft Windows™ XP Service Pack 1 (use latest available Service Pack)
Note: For Windows™ 95, operating system must support USB ports (OSR2 version is needed) if a USB
Dongle is to be used.
Software Installation
Synergy Manager Software installation uses InstallShield installation software. Please read this section in its
entirety before attempting installation.
1. First close all running programs.
2. Uninstall any previous versions of Synergy Manager including ‘Monitor Only’ versions before
installing this new version. Previous versions of this software are not compatible.
3. Insert the installation CD into the proper drive and navigate to drive root folder. If necessary unzip
program files into a temporary folder before proceeding to next step.
4. Do not insert the Dongle key until application has been properly installed.
5. Run the Synergy Manager Setup program (LinkTenn32_Setup.exe) file from the run option of the
start menu.
6. Follow the installation instructions on the screen.
Содержание Synergy Compact
Страница 14: ...Synergy Controller Technical Manual Revision H Page 14 2 0 SPECIFICATIONS 2 1 Data Sheet...
Страница 71: ...Synergy Controller Technical Manual Revision H Page 71...
Страница 106: ...Synergy Controller Technical Manual Revision H Page 106...
Страница 123: ...Synergy Controller Technical Manual Revision H Page 123...
Страница 141: ...Synergy Controller Technical Manual Revision H Page 141 TE1151 6 Triac Output Board Schematic...
Страница 142: ...Synergy Controller Technical Manual Revision H Page 142 TE1708 6 Relay Board Schematic...
Страница 188: ...Synergy Controller Technical Manual Revision H Page 188...
Страница 274: ...Synergy Controller Technical Manual Revision H Page 274 Synergy Controller Step Syntax...
Страница 294: ...Synergy Controller Technical Manual Revision H Page 294...
Страница 312: ...Synergy Controller Technical Manual Revision H Page 312...
Страница 345: ...Synergy Controller Technical Manual Revision H Page 345...
Страница 346: ...Synergy Controller Technical Manual Revision H Page 346...