Operating manual

Data acquisition system

PWBlogg

Type:     N6/40

Содержание PWBlogg N6/40

Страница 1: ...Operating manual Data acquisition system PWBlogg Type N6 40...

Страница 2: ...llenstedt All rights reserved No section of the operating manual may be replicated or processed duplica ted or distributed using electronic systems in any way print photocopy microfilm or other me tho...

Страница 3: ...repair All subsequent modifications to the device result in the consequence that a secure use is no more guaranteed within ex zone 2 and the EC declaration of conformity loses ist validity 3 Safety p...

Страница 4: ...ters 6 2 2 Error sources 7 2 3 Data communication 7 3 Charging the built in accumulator 9 4 Technical specifications 9 4 1 Data logger 9 4 2 Explosion protection optional 10 4 3 Data memory 10 4 4 Est...

Страница 5: ...r The measurement range begins at 50 mbar Data logger The data logger has an integrated analog digital converter with high resolution which is responsible for logging and digitizing pressure and tempe...

Страница 6: ...resholds and records threshold violations by means of a se cond sample rate Additional to the threshold a hysteresis can be specified Important parameters to monitor thresholds are described as follow...

Страница 7: ...s are non linearities of AD converter which are irrelevant on resolution of 8 bit or 12 bit However another important one is the digital step at small resolutions At the limit of two sequent digital v...

Страница 8: ...8 Paul Wegener GmbH Performance data evaluation can be done in tabular form or as chart Individual periods can be enlarged by the integrated zoom function...

Страница 9: ...in power saving mode If the accumulator s residual capacity falls below 20 then at the latest it should be recharged We recommend 100 charging prior to any operation The accumulator must not be replac...

Страница 10: ...umber of channels occupied from preset sample intervals 1 and 2 as well as from storage and sample mode If the reading resolution is 8 bit 12 14 or 16 bit possible storage times will halve themselves...

Страница 11: ...business and trade as well as small firms EN 61000 6 2 subject standard for interference resistance industrial sector EN 60079 0 electrical equipment for explosion hazard areas section 0 general requi...

Страница 12: ...umulator is low Have it replaced by manufacturer Password forgotten Read out performance data send reading file to manufacturer Software does not read per formance data comple tely or reports errors w...

Страница 13: ...Operating manual of data acquisition system PWBlogg 13...

Страница 14: ...14 Paul Wegener GmbH...

Страница 15: ...Operating manual of data acquisition system PWBlogg 15...

Страница 16: ...r GmbH Tel Fax Internet e mail 49 0 39483 96 300 49 0 39483 96 400 www paul wegener de info paul wegener de Most recent emendment 01 08 2013 PWB FORM 2085 EN13 Paul Wegener GmbH Marienstra e 24 D 0649...