1
Getting Familiar with Your TriPlus RSH
Instrument Basics
2
TriPlus RSH User Guide
Thermo Scientific
Instrument Basics
The TriPlus RSH, offers you great flexibility in various applications. A unique automated tool
changer is provided, increasing throughput and allowing sample preparation steps before the
injection cycle. Refer to the Prep Cycles
Calibration Dilution
and
Standard Addition
.
The new versatility and seminal technical aspects are highlighted.
The TriPlus RSH has several advantages for use and provides greater flexibility and security
for routine and research applications, including:
• System Setup using the Virtual Handheld Controller software (or optional Handheld
Controller).
• Guided teaching wizards for tools and modules.
• The future-oriented
Servo motor
— a new control concept for motors with a high
intelligence, providing high security on X-,Y-, and Z-positioning at any time.
• The communication Bus increases the flexibility for adding so-called
Active modules
and
controlling these modules in a bidirectional manner. A self-detection mode simplifies the
addition of a module to the TriPlus RSH configuration.
The bidirectional communication allows control of the module at any given time or
position. Data stored in a log file not only gives you a high degree of security but also
facilitates the tractability of cycle performance, providing easy access to essential
information which might be requested by inspection authorities.
• A unique ATC Station allows an automated change of Tools (syringes with different
volumes or different tool types) for advanced sampling preparation, liquid handling
(dilutions), derivatization steps or any other time-consuming repetitive step. This added
versatility alongside the increase in throughput are significant benefits for you.
• New optional hardware modules, for example the Vortexer, for efficient phase mixing,
expands the range of applications and adds to the system versatility.
• A large range of syringe volumes is available for liquid or gaseous sample injection for
different GC-injector types (split/splitless, on-column, and so on.) and GC-columns
(from micro capillary to packed columns) enhancing the available options for you.
• A large range of vial sizes or microtiter plates which can be used in various tray holders.
• Vial bottom sensing allows aspiration of the very last drop in a vial.
• Barcode reader with dual scan module for barcode identification in any position.
• Wide range of predefined cycles for advanced liquid handling.
The TriPlus RSH can be set up and configured using either the Handheld Controller or
the Virtual Handheld Controller (PC software).
The options and parameters are identical, but the handling differs between the Handheld
Controller (Scroll Wheel and
Enter
button) and the normal control within the software.
The setup procedure is described in the sections