Overview of Operating Modes
Teledyne API
– T200 NO/NO
2
/NO
X
Analyzer Operation Manual
76
DISPLAY
PARAMETER
UNITS
DESCRIPTION
HVPS
HVPS
V
The output power level of the high voltage power supply.
RCELL TEMP
RCELLTEMP
C
The temperature of the gas inside the reaction cell temperature.
BOX TEMP
BOXTEMP
C
The temperature inside the analyzer chassis.
PMT TEMP
PMTTEMP
C
The temperature of the PMT .
IZS TEMP
1
IZSTEMP
C
The temperature of the internal span gas generator's permeation tube.
MOLY TEMP
CONVTEMP
C
The temperature of the analyzer's
NO
2
NO converter.
RCEL
RCELLPRESS
IN-HG-A
The current pressure of the sample gas in the reaction cell as measured at
the vacuum manifold.
SAMP
SAMPPRESS
IN-HG-A
The current pressure of the sample gas as it enters the reaction cell,
measured between the NO/NO
x
and Auto-Zero valves.
NOX SLOPE
NOXSLOPE
The slope calculated during the most recent NO
x
zero/span calibration.
NOX OFFS
NOXOFFSET
MV
The offset calculated during the most recent NO
x
zero/span calibration.
NO SLOPE
NOSLOPE
The slope calculated during the most recent NO zero/span calibration.
NO OFFS
NOOFFSET
MV
The offset calculated during the most recent NO zero/span calibration.
TEST
TESTCHAN
MV
Displays the signal level of the Test Function that is currently being
produced by the Analog Output Channel
A4
.
TIME
CLOCKTIME
HH:MM:SS
The current time. This is used to create a time stamp on DAS readings,
and by the AutoCal feature to trigger calibration events.
1
Only appears if Internal Span Gas Generator option is installed.
I
MPORTANT
I
MPACT ON
R
EADINGS OR
D
ATA
A value of ―XXXX‖ displayed for any of the TEST functions indicates an out-of-
range reading or the
analyzer’s inability to calculate it. All pressure
measurements are represented in terms of absolute pressure. Absolute,
atmospheric pressure is 29.92 in-Hg-A at sea level. It decreases about 1 in-Hg
per 300 m gain in altitude. A variety of factors such as air conditioning and
passing storms can cause changes in the absolute atmospheric pressure.
06858E DCN7057
Содержание T200
Страница 2: ......
Страница 4: ...ii This page intentionally left blank 06858E DCN7057 ...
Страница 8: ...vi This page intentionally left blank 06858E DCN7057 ...
Страница 344: ...Index Teledyne API T200 NO NO2 NOX Analyzer Operation Manual 342 This page intentionally left blank 06858E DCN7057 ...
Страница 380: ...This page intentionally left blank B 2 06858E DCN7057 ...
Страница 384: ...This page intentionally left blank B 6 06858E DCN7057 ...
Страница 387: ...APPENDIX D Wire List and Electronic Schematics 06858E DCN7057 D 1 ...
Страница 388: ...This page intentionally left blank D 2 06858E DCN7057 ...
Страница 393: ...06858E DCN7057 D 7 ...