Introduction
Teledyne API
– T200 NO/NO
2
/NO
X
Analyzer Operation Manual
18
Option
Option
Number
Description/Notes
Reference
minute, calibration performed at a tube temperature of 50°C.
Communication Cables
For remote serial, network and Internet communication with the analyzer.
Type
Description
60A
RS-232
Shielded, straight-through DB-9F to DB-25M cable, about
1.8 m long. Used to interface with older computers or
code activated switches with DB-25 serial connectors.
Section 3.3.1.8
60B
RS-232
Shielded, straight-through DB-9F to DB-9F cable of about
1.8 m length.
Section 3.3.1.8
60C
Ethernet
Patch cable, 2 meters long, used for Internet and LAN
communications.
Section 3.3.1.8
60D
USB
Cable for direct connection between instrument (rear
panel USB port) and personal computer.
Section 3.3.1.8
USB Port
For remote connection
64A
For connection to personal computer. (Separate option only when
Option 64B,
Analog Input and USB Com Port
not elected).
Concentration Alarm Relays
Issues warning when gas concentration exceeds limits set by user.
61
Four (4) “dry contact” relays on the rear panel of the instrument. This
relay option is different from and in addition to the “Contact Closures”
that come standard on all TAPI instruments.
Section 3.3.1.7
RS-232 Multidrop
Enables communications between host computer and up to eight analyzers.
62
Multidrop card seated on the analyzer’s CPU card.
Each instrument in the multidrop network requres this card and a
communications cable (Option 60B).
Section 3.3.1.8
Other Gas Options
Second gas sensor and gas conditioners
65A
Oxygen (O
2
) Sensor
86A
Ammonia removal sample conditioner (required for EN Certification)
86C
External zero air scrubber
Sections 3.3.2.6,
9.1.2.1, 11.3.7, and
11.3.7.1, Table 11-1
Special Features
Built in features, software activated
N/A
Maintenance Mode Switch
, located inside the instrument, places
the analyzer in maintenance mode where it can continue sampling,
yet ignore calibration, diagnostic, and reset instrument commands.
This feature is of particular use for instruments connected to
Multidrop or Hessen protocol networks.
Call Customer Service for activation.
(TAPI Tech
Support)
N/A
Second Language Switch
activates an alternate set of display
messages in a language other than the instrument’s default
language.
Call Customer Service for a specially programmed Disk on Module containing
the second language.
(TAPI Tech
Support)
N/A
Dilution Ratio Option
allows the user to compensate for diluted
sample gas, such as in continuous emission monitoring (CEM) where
the quality of gas in a smoke stack is being tested and the sampling
method used to remove the gas from the stack dilutes the gas.
Call Customer Service for activation.
Section 5.4.3.5
06858E DCN7057
Содержание T200
Страница 2: ......
Страница 4: ...ii This page intentionally left blank 06858E DCN7057 ...
Страница 8: ...vi This page intentionally left blank 06858E DCN7057 ...
Страница 344: ...Index Teledyne API T200 NO NO2 NOX Analyzer Operation Manual 342 This page intentionally left blank 06858E DCN7057 ...
Страница 380: ...This page intentionally left blank B 2 06858E DCN7057 ...
Страница 384: ...This page intentionally left blank B 6 06858E DCN7057 ...
Страница 387: ...APPENDIX D Wire List and Electronic Schematics 06858E DCN7057 D 1 ...
Страница 388: ...This page intentionally left blank D 2 06858E DCN7057 ...
Страница 393: ...06858E DCN7057 D 7 ...