uPrint/uPrint SE Service Manual
5-29
32.
Add the lengths derived from steps
and
(A-E and E-I) and then subtract the width
of circle E derived from step
. Record this total as “GLF”
33.
Enter the Service Calibration menu by pressing the following button sequence on the
display panel:
3,2,3,3,1
. See
34.
Press the
Edit Configuration
button.
35.
Press the
GLeft
button. Enter the value recorded from step
Increment
,
Decrement
and
Next Digit
buttons.
36.
When finished, press
Done...
37.
Press the
GRight
button. Enter the value recorded from step
by pressing the
Increment
,
Decrement
and
Next Digit
buttons.
38.
When finished, press
Done...
39.
Press the
GFront
button. Enter the value recorded from step
by pressing the
Increment
,
Decrement
and
Next Digit
buttons.
40.
When finished, press
Done...
41.
Press the
Next...
button.
42.
Press the
GRear
button. Enter the value recorded from step
Increment
,
Decrement
and
Next Digit
buttons.
43.
When finished, press
Done...
44.
Press the
GLF
button. Enter the value recorded from step
by pressing the
Increment
,
Decrement
and
Next Digit
buttons.
45.
When finished, press
Done...
46.
Press the
GLR
button. Enter the value recorded from step
by pressing the
Increment
,
Decrement
and
Next Digit
buttons.
47.
When finished, press
Done...
48.
Press the
Next...
button until you reach the last page.
49.
Press the
Done...
button.
50.
Press the
Save and reboot
button.
51.
The printer will reboot and return to idle.
52.
Build a sample part to verify proper operation.
Note:
The value for GLeft must be between 5.250 and 5.750, the
Done...
button will
not appear until the value is within the acceptable range.
Note:
The value for GRight must be between 5.250 and 5.750, the
Done...
button
will not appear until the value is within the acceptable range.
Note:
The value for GFront must be between 7.250 and 7.750, the
Done...
button
will not appear until the value is within the acceptable range.
Note:
The value for GRear must be between 7.250 and 7.750, the
Done...
button
will not appear until the value is within the acceptable range.
Note:
The value for GLF must be between 10.357 and 10.857, the
Done...
button
will not appear until the value is within the acceptable range.
Note:
The value for GLR must be between 10.357 and 10.857, the
Done...
button
will not appear until the value is within the acceptable range.
Содержание uPrint
Страница 1: ...uPrint and uPrint Plus uPrint SE and uPrint SE Plus Service Manual Part No 209010 0001 Rev D...
Страница 11: ...1 2...
Страница 35: ...2 24...
Страница 178: ...uPrint uPrint SE Service Manual 4 131 Figure 4 230 uPrint and uPrint SE measurement points and worksheet BL FL FR BR...
Страница 179: ...4 132 Figure 4 231 uPrint Plus and uPrint SE Plus measurement points and worksheet BL FL FR BR...
Страница 207: ...4 160 Figure 4 275 uPrint and uPrint SE measurement points and worksheet BL FL FR BR...
Страница 267: ...5 58...
Страница 343: ...6 76...
Страница 359: ...7 16...
Страница 373: ...8 14...