uPrint/uPrint SE Service Manual
6-19
14,96 Unidentified interrupt
occurred
1.
Cycle power.
14,97 Invalid data type
1.
Cycle power.
14,98 Find home failed, X EOT time-
out
14,99 Find home failed, Y EOT time-
out
1.
Power cycle machine - remember to move head away from switches.
2.
Using LED's check to see limit box toggles when switch is activated. If
not, check switch and/or umbilical cable for X, Y cable for Y.
3.
X errors - Check pins and re-seat connector J505 on the I/O Card. Y
errors - Check pins and re-seat connector J503 on the I/O Card.
14,100 Find home failed, Z HOME
(BOT) not tripped
14,101 Find home failed, Z EOT not
tripped
14,102 Find home failed, Z HOME
(BOT) time-out
14,103 Find home failed, Z EOT time-
out
1.
Check for objects/parts on Z stage and around lead screw.
2.
Cycle power.
3.
Check Z Home and Z EOT LED's on PDB to verify state changes
correctly. If not, check connector P8 on the PDB and Z switches.
Replace cable and/or switches.
4.
Replace Z axis motor and lead screw.
5.
14.101 error only - Check 5/12 VDC power (5 and 12VDC LEDs will
repeatedly dim) Replace 5/12 VDC power supply.
14,104 Surface not found
1.
No modeling base. Install modeling base.
2.
Modeling base is used/defective, has low spot. Replace Modeling
base.
3.
Verify substrate sensor is working. If not, replace Substrate Sensor.
14,105 Controller not ready to build a
model
1.
Cycle power.
14,106 BOT offset is higher than the
BOT switch
1.
Use MaracaEX to zero the Z offset value.
2.
Run tip Z calibration.
3.
Check Z home sensor.
14,107 End model command while
not modeling
Software error; will not be displayed.
14,108 Operation was killed
Software error; will not be displayed.
14,109 Out of memory
Software error; will not be displayed.
14,110 Cartridge communication
error
1.
Replace material spool.
2.
Replace material carrier.
3.
Replace material bay.
14,111 Invalid frame check sequence
1.
Cycle power.
2.
If error repeats, replace Controller Board.
14,112 EEPROM communication error
Software error; will not be displayed.
14,113 Door not latched
1.
Verify chamber fans are operational. If not, replace 24VDC power
supply.
2.
Inspect solenoid and wiring.
3.
Replace solenoid.
4.
Replace PDB.
14,114 Thermocouple snap switch
tripped
Not used on uPrint, uPrint SE, uPrint Plus and uPrint SE Plus printers.
14,115 Z stage planarity beyond toler-
ance
1.
Replace modeling base.
2.
Re-level XY table.
14,116 I2C configuration info is cor-
rupt
Software error; will not be displayed.
14,117 A command failed while mod-
eling
1.
Download CFG file - check error code details.
2.
Toggle failure - reference 14,129.
3.
Check and re-seat connectors/pins on J506 on the I/O card and J301
on the head board.
4.
Replace Toggle Head assembly.
5.
Replace PDB (U8 chip failure).
14,118 Invalid cyclic redundancy
check
Software error; will not be displayed
Code
Description
Corrective Actions
Содержание uPrint
Страница 1: ...uPrint and uPrint Plus uPrint SE and uPrint SE Plus Service Manual Part No 209010 0001 Rev D...
Страница 11: ...1 2...
Страница 35: ...2 24...
Страница 178: ...uPrint uPrint SE Service Manual 4 131 Figure 4 230 uPrint and uPrint SE measurement points and worksheet BL FL FR BR...
Страница 179: ...4 132 Figure 4 231 uPrint Plus and uPrint SE Plus measurement points and worksheet BL FL FR BR...
Страница 207: ...4 160 Figure 4 275 uPrint and uPrint SE measurement points and worksheet BL FL FR BR...
Страница 267: ...5 58...
Страница 343: ...6 76...
Страница 359: ...7 16...
Страница 373: ...8 14...