5-30
Performing part based calibration for uPrint Plus and uPrint SE Plus with MaracaEX
1.
Open MaracaEX and select the current modeler from the pull down menu.
2.
Open
Gantry Calibration
Dialog box in MaracaEX
3.
Set the X adjust value to 0.
4.
In the Part Calibration section, there are six boxes: LEFT, RIGHT, FRONT, REAR, LEFT
FRONT and LEFT REAR.
Set these values to 0.
5.
Click on the green check mark to save the values.
6.
Toggle the system power down switch.
7.
Once the system displays Idle, press
Maintenance>System>Test Parts
then
select
the
test_XY_cal
part.
8.
When part is completed, remove from printer and let cool for five minutes.
9.
Locate the filled circle, this indicates the front of the substrate, see
Figure 5-333: Locating the Filled Circle (B)
10.
Using a digital caliper, measure and record the diameter of circle B along the center line
between A and C, see
Figure 5-334: Measuring diameter of B
11.
Next measure and record the distance from the outside edges of circle A and B, see
Note:
Reference letters are not actually “printed” on the part. If needed, use the
Part Measurement Equations sheet to record the values. See
Содержание uPrint
Страница 1: ...uPrint and uPrint Plus uPrint SE and uPrint SE Plus Service Manual Part No 209010 0001 Rev D...
Страница 11: ...1 2...
Страница 35: ...2 24...
Страница 178: ...uPrint uPrint SE Service Manual 4 131 Figure 4 230 uPrint and uPrint SE measurement points and worksheet BL FL FR BR...
Страница 179: ...4 132 Figure 4 231 uPrint Plus and uPrint SE Plus measurement points and worksheet BL FL FR BR...
Страница 207: ...4 160 Figure 4 275 uPrint and uPrint SE measurement points and worksheet BL FL FR BR...
Страница 267: ...5 58...
Страница 343: ...6 76...
Страница 359: ...7 16...
Страница 373: ...8 14...