uPrint/uPrint SE Service Manual
6-67
Figure 6-387: Setup Serial Port
92.
93.
9.
From the
Baud Rate:
pull-down menu select
38400
10.
From the
Flow Control:
pull-down menu select
hardware
11.
The rest of the settings should default to the correct values. Click
OK
, see
Figure 6-388: Serial Port Setup
94.
95.
12.
The connection should now be established.
A.
To test the connection, type
ss
and press the
Enter
key. “Information should post
on the screen if the connection was successful.
96.
Note:
If text does not appear in TeraTerm you may have the wrong COM Port
selected, there may be an issue with the Null Modem Cable or there may be an
issue with the USB to serial converter.