5-2
Offset Calibrations
Adjusting Z Calibration and XY Tip Offset
Z calibration is needed to adjust the slight differences in tip heights. XY Tip Offset is
required to correct for the slight differences in tip alignment. Failure to perform these
calibrations will result in poor part quality and possible LOE’s.
Z and Tip Offset calibrations are
mandatory
whenever the tips are replaced. If
Tip
Replacement
is chosen from the Interface Panel
Maintenance>Machine>Tip>Replace
, you will be
prompted to perform the calibrations as a part of the replacement procedure.
These calibrations can also be run without performing a Tip Replacement. From
Idle
, choose
Maintenance>Machine>Tip
then
Calibrate Z
or
Calibrate XY
.
Z Calibration
Typical Z calibration
1.
Press
Maintenance.
2.
Press
Machine.
3.
Press
Tip.
4.
Press
Calibrate Z.
5.
Press
Start Part
. The printer will automatically build a Z Calibration part (one square of
model and one of support). The system will then measure and calibrate the Z Axis for tip
depth and tip level. (Build time is approximately 5 minutes).
6.
Repeat steps 1-5 to verify proper calibration.
Caution:
Do not use the Z calibration or XY tip offset from the test parts menu to
calibrate the system.
Note:
Unusual circumstances may require that the Z calibration values be entered
manually. To change these values, see
Entering Z Calibration values manually
Содержание uPrint
Страница 1: ...uPrint and uPrint Plus uPrint SE and uPrint SE Plus Service Manual Part No 209010 0001 Rev D...
Страница 11: ...1 2...
Страница 35: ...2 24...
Страница 178: ...uPrint uPrint SE Service Manual 4 131 Figure 4 230 uPrint and uPrint SE measurement points and worksheet BL FL FR BR...
Страница 179: ...4 132 Figure 4 231 uPrint Plus and uPrint SE Plus measurement points and worksheet BL FL FR BR...
Страница 207: ...4 160 Figure 4 275 uPrint and uPrint SE measurement points and worksheet BL FL FR BR...
Страница 267: ...5 58...
Страница 343: ...6 76...
Страница 359: ...7 16...
Страница 373: ...8 14...