uPrint/uPrint SE Service Manual
6-29
52.
53.
1.
Part Geometry Failure
- Model or support features fell
over
1.
Reorient, reprocess and resubmit the part
2.
Run Z calibration
3.
Replace tip shields and tip wipe assembly
4.
If part has shifted in X or Y, refer to part quality section, part shift subsection.
5.
In case of Z shift:
a. Realign Z guide rods.
b. Replace Z motor and leadscrew.
6.
Replace Z assembly.
1.
Excess Material Inside Head
- Filament Buckled / Spaghetti
Head
- Encased Head
1.
Check for loose heater block clamp screws.
2.
Make sure the head connectors are seated properly.
3.
Check air plenum for: proper hose connection; properly seating; cracks or
damage.
4.
Check to make sure head blower fan hose is connected to blower.
5.
If extrusion fails on first layer with a used modeling base, retry with a new one
6.
Rerun Z calibration
7.
Plugged Liquefier - replace tips.
8.
Inspect model for excessive overfill.
a. Toolpaths should not overlap by more than 50%. If so, reorient and
reprocess STL.
b. If model curl has caused the part to contact the tip, reprocess part with
less dense fill. Re-run tip Z cal if part is separating from supports
c. If part curl continues, see part curl section
9.
Check idler wheel gap.
10. Check liquefier alignment.
11. Head idler spring is deformed or installed improperly. Replace head idler
spring.
12. Possible head temperature issue
a. Replace head board and TC Amp board.
b. Replace toggle head assembly.
13. Head motor power wires or encoder failure - replace toggle head
14. Blower fan not supplying enough air flow - weak or stalling. Replace fan.
15. Replace umbilical cable
16. Replace controller board
17. In case of Z shift:
a. Realign Z guide rods.
b. Replace Z motor and leadscrew.
c. Replace Z assembly.
1.
Filament motor is running very
fast.
1.
Make sure the head connectors are seated properly.
2.
Bad motor. Replace toggle head assembly.
3.
Broken wire in the umbilical cable. Replace umbilical cable.
I. Lights
Chamber lights won't come
on or are dim. (Unit is other-
wise functioning normally)
1.
Check and re-seat connectors to the light bar.
2.
Lights are burnt out - replace light bars.
3.
Check for continuity in upper harness cable. If no continuity, replace upper
harness.
Содержание uPrint
Страница 1: ...uPrint and uPrint Plus uPrint SE and uPrint SE Plus Service Manual Part No 209010 0001 Rev D...
Страница 11: ...1 2...
Страница 35: ...2 24...
Страница 178: ...uPrint uPrint SE Service Manual 4 131 Figure 4 230 uPrint and uPrint SE measurement points and worksheet BL FL FR BR...
Страница 179: ...4 132 Figure 4 231 uPrint Plus and uPrint SE Plus measurement points and worksheet BL FL FR BR...
Страница 207: ...4 160 Figure 4 275 uPrint and uPrint SE measurement points and worksheet BL FL FR BR...
Страница 267: ...5 58...
Страница 343: ...6 76...
Страница 359: ...7 16...
Страница 373: ...8 14...