6-20
14,119 Operation already active
Software error; will not be displayed
14,120 Invalid vector detected
1.
Reprocess the part and send again.
2.
Reorient part and send again.
3.
If the frequency of the error is greater than once every three months,
then replace the SBC or hard drive.
14,121 Processor Exception
1.
Cycle power.
14,122 Processor halted
1.
Cycle power.
14,123 Watchdog time-out
1.
Cycle power.
2.
Check all cable connections including thermocouples.
3.
Escalate the case providing .cfg file.
14,124 Stack overflow
1.
Cycle power.
2.
If problem persists, replace Controller Board.
14,125 Runtime error
1.
Cycle power.
14,126 Operation active - try again
1.
Cycle power.
14,127 Invalid gender
1.
Cycle power.
2.
If problem persists, replace Controller Board.
14,128 Invalid platform
1.
Cycle power.
2.
If problem persists, replace Controller Board.
14,129 Toggle Head failure
1.
Check physical position of head at failure.
2.
Ensure toggle bar aligns with toggle stops.
3.
Inspect top layer of model for part shift.
4.
If any of above indicate a failure, Cycle Power and re-send part.
5.
Remove head cover, Verify that you can manually toggle the head.
and check liquefier inlets for excessive material build up. Remove if
present.
6.
Check and re-seat connectors/pins on J506 on the I/O card and J301
on the Head Board.
7.
Re-seat toggle connector on the Head Board.
8.
Check Model and Support Toggle LED's on PDB. Verify high and low
states.
•
On head board for toggle signal: TP201-Model; TP101-Support
9.
Using TeraTerm run AH to toggle the head. Monitor system movement
to help determine root cause of issue.
10. Replace Toggle Sensor Board.
11. Replace Head Board.
12. Replace Toggle Head assembly.
14,130 Temperature setback is active
1. Cycle power.
14,131 Toggle when head motor is
running
1.
Check Model and Support Toggle LED's on PDB. Verify high and low
states.
•
On head board for toggle signal: TP201-Model; TP101-Support
2.
Re-seat connectors on the Head Board.
3.
Replace Toggle Sensor Board.
4.
Replace Head Board.
5.
Replace Umbilical Cable.
14,132 UPS low power
1.
UPS is shutting down. Check UPS and AC power.
Code
Description
Corrective Actions
Содержание uPrint
Страница 1: ...uPrint and uPrint Plus uPrint SE and uPrint SE Plus Service Manual Part No 209010 0001 Rev D...
Страница 11: ...1 2...
Страница 35: ...2 24...
Страница 178: ...uPrint uPrint SE Service Manual 4 131 Figure 4 230 uPrint and uPrint SE measurement points and worksheet BL FL FR BR...
Страница 179: ...4 132 Figure 4 231 uPrint Plus and uPrint SE Plus measurement points and worksheet BL FL FR BR...
Страница 207: ...4 160 Figure 4 275 uPrint and uPrint SE measurement points and worksheet BL FL FR BR...
Страница 267: ...5 58...
Страница 343: ...6 76...
Страница 359: ...7 16...
Страница 373: ...8 14...