
7-12
6.
Verify the tip is fully inserted into the heater block and that the stainless steel shield is
aligned. See
7.
Use 7/64 T-Handle Allen wrench to firmly tighten the heater block clamp screws. See
Figure 7-413: Installation Examples
8.
Repeat steps 3 through 7 for the other tip if necessary.
9.
Install a new tip shield by pushing it over the exposed tip, keeping the slotted end
toward the back of the head. See
Figure 7-414: Tip shield installation
Note:
Make sure the tip remains all the way up against the heater block as you
tighten the screws.
Note:
Tip shield should be flush with the tip plate as shown in
INCORRECT -
Shield
interference
INCORRECT -
Tip not seated
CORRECT
Содержание uPrint
Страница 1: ...uPrint and uPrint Plus uPrint SE and uPrint SE Plus Service Manual Part No 209010 0001 Rev D...
Страница 11: ...1 2...
Страница 35: ...2 24...
Страница 178: ...uPrint uPrint SE Service Manual 4 131 Figure 4 230 uPrint and uPrint SE measurement points and worksheet BL FL FR BR...
Страница 179: ...4 132 Figure 4 231 uPrint Plus and uPrint SE Plus measurement points and worksheet BL FL FR BR...
Страница 207: ...4 160 Figure 4 275 uPrint and uPrint SE measurement points and worksheet BL FL FR BR...
Страница 267: ...5 58...
Страница 343: ...6 76...
Страница 359: ...7 16...
Страница 373: ...8 14...