uPrint/uPrint SE Service Manual
3-11
Get Calibration
The Get Calibration button allows a single calibration file to be retrieved from any machine
with a build number greater than or equal to 1132. This calibration file will also be on the
system calibration floppy disk/CD that ships in the electronics pan for systems with a build
number greater than or equal to 1132. This file contains all the factory calibration
information, including, but not limited to: Tip Offset, Tip Depth, Y Lash, X Correction, and
the table calibration DAT file.
When the button is pressed, a file selection dialog is presented allowing the assignment of a
file name and the selection of a storage location. This file should be updated any time
maintenance is performed that affects the factory calibration.
Send Calibration
The Send Calibration button allows you to send the complete set of factory calibrations to the
machine as a single file. This includes but is not limited to: Tip Offset, Tip Depth, YLash, X
Correction, and the gantry DAT file. This file is stored on the system calibration floppy disk/
CD if the system shipped with Controller software build 1132 or higher installed. A
calibration file can be retrieved from the modeler using Get Calibration from any system
with a build number of 1132 or higher.
When this button is pressed a dialog box appears that allows you to browse for and select the
calibration file to send to the machine.
Get Config
When the Get Config button is pressed a file selection dialog is presented allowing the
assignment of a file name and the selection of a storage location.
Test Parts
Test Parts consists of downloading sample and test part files to the machine. These file must
be in the .cmb.gz format produced by CatalystEX.
The Test Part dialog allows you to browse for and select the sample or test file and to
download it to the machine. The Test Parts are not preserved during a software upgrade. To
remove unwanted test parts, upgrade the software to the current level and only the factory
test parts will remain on the system.
Reset Password
This button resets the administrator password to null. This turns off password control of the
queue. This is used for clearing a forgotten password.
Содержание uPrint
Страница 1: ...uPrint and uPrint Plus uPrint SE and uPrint SE Plus Service Manual Part No 209010 0001 Rev D...
Страница 11: ...1 2...
Страница 35: ...2 24...
Страница 178: ...uPrint uPrint SE Service Manual 4 131 Figure 4 230 uPrint and uPrint SE measurement points and worksheet BL FL FR BR...
Страница 179: ...4 132 Figure 4 231 uPrint Plus and uPrint SE Plus measurement points and worksheet BL FL FR BR...
Страница 207: ...4 160 Figure 4 275 uPrint and uPrint SE measurement points and worksheet BL FL FR BR...
Страница 267: ...5 58...
Страница 343: ...6 76...
Страница 359: ...7 16...
Страница 373: ...8 14...